REGULATOR HOSE ASSEMBLY CHECK:
Clean and inspect the hose before each use of
the appliance. If there is evidence of abrasion,
wear, cuts or leaks the hose must be replaced
prior to the appliance being put into operation.
The replacement hose assembly must be the
one specified by the manufacturer.
INSTRUCTIONS FOR LIGHTING BURNER:
1. Read all instructions before lighting. Only
light burner outdoors.
2. Confirm that the regulator control valve and
cylinder valve are completely closed and in
the OFF position.
3. Ensure a minimum
of 24 inches
(61 cm) separate
the LP tank and
the appliance.
WARNING
LP hose is a tripping hazard.
Special Care must be observed.
4. Open the LP tank valve fully by turning
counterclockwise.
5. Open regulator control valve by turning
clockwise until fully open.
6. Using a long ignited
match (fireplace
match), place flame
directly over the burner.
If using a short/paper
book match, first place
the unlit match into the match holder which
is attached by a chain to the fryer stand,
then light the match.
Match Holder
7. Push upward and continually hold the
orange button on the safety valve until the
burner is lit. DO NOT stand with head or
lococookers.com
OPERATING INSTRUCTIONS
arms over burner.
After the burner is lit,
continue to hold the
button on the safety
valve for 30 seconds
and then release.
8. If ignition does not occur in 5 seconds,
turn the regulator control valve OFF, wait 5
minutes, then repeat the lighting procedure.
9. When the burner is lit, turn the regulator
control valve to the desired heat output
position between ON and OFF.
SMART TEMP HEAT SENSOR:
Your fryer is equipped with a Smart Temp heat
sensor. Make sure the cooking pot is properly
seated in the stand so
that the cooking pot
touches the sensor. If
the oil gets too hot the
sensor will extinguish
the flame. If this occurs,
allow the oil to cool and
restart the burner. See
"INSTRUCTIONS FOR LIGHTING BURNER."
SHUT DOWN INSTRUCTIONS:
1. Turn LP tank OFF by turning hand wheel
clockwise to a full stop.
2. Turn regulator control valve
counterclockwise to the OFF position.
WHEN BURNER FLAME IS ACCIDENTALLY
EXTINGUISHED:
1. Turn LP tank OFF by turning hand wheel
clockwise to a full stop.
2. Turn regulator control valve
counterclockwise to the OFF position.
3. Inspect the hose and make sure connections
are complete. After waiting 5 minutes, restart
the appliance following "INSTRUCTIONS
FOR LIGHTING BURNER."
OFF
LP Tank
Hand Wheel
OFF
Regulator
Control Valve
11