Care And Maintenance - Metabo DFP 400 Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
en
ENGLISH
3. Screw the grease reservoir (11) back in place
in a clockwise direction. Do not secure too
tightly.
4. Holding the plunger rod catch (10) down, insert
the plunger rod (9).
Filling the gun from bulk containers
1. Unscrew the grease reservoir (11), turning it
counter-clockwise to release.
2. Immerse the grease reservoir (11) approxi-
mately 5 cm in the grease and slowly pull back
the plunger rod (9) as far as it will go.
3. Screw the grease reservoir (11) back in place
in a clockwise direction.
4. Holding the plunger rod catch (10) down, insert
the plunger rod (9).
Filling the grease gun with a filler pump
1. Withdraw the plunger rod (9) as far as it will go.
2. Connect the filler neck (2) to the filler pump.
3. Switch on the filler pump and fill the grease res-
ervoir (11) completely.
4. Disconnect the filler neck (2) from the filler
pump.
5. Holding the plunger rod catch (10) down, insert
the plunger rod (9).
6.3
Using the air tool
To benefit from the air tool's full performance,
always use compressed air hoses with an inner
diameter of at least 9 mm. Tool performance can be
significantly impaired if the inner diameter is too
small.
Caution. The compressed air line must not
contain any water condensation.
Caution. To preserve and extend the service
life of this tool, you must ensure that it is regu-
12
All manuals and user guides at all-guides.com
larly maintained with pneumatic oil lubricator. You
can do this as follows:
– Use oiled compressed air by fitting an oil-fog lu-
bricator.
– Without an oil-fog lubricator: manually apply oil
every day via the compressed air connection.
Use approx. 3-5 drops of pneumatic oil lubricator
for each 15 minutes of continuous operation.
If the tool has not been in use for several days, you
should manually apply about 5 drops of pneumatic
oil lubricator into the compressed air connection.
1. Tighten either the lubrication tube (1) or lubrica-
tion hose (12) in a clockwise direction on the
head (4).
2. Adjust the supply pressure on the compressor
(for the maximum permissible supply pressure,
see Technical Specifications).
3. Connect the tool by means of a quick coupling
to the compressed air supply.
4. Engage the grease gun with the lubrication nip-
ple.
5. To deliver the grease, press the trigger (5).
6. Release the trigger (5) as soon as sufficient
grease has been delivered to the lubrication
nipple.
Note:
For the device to be lubricated, refer to the manu-
facturer's instructions for information about the
required pressure, lubrication interval, lubricant
type and quantity.
.

7. Care and Maintenance

Danger! Disconnect the compressed air con-
nection before carrying out any work.
Danger! Repair and maintenance work other
than described in this section should only be
carried out by qualified specialists.
- Carry out regular maintenance to ensure the
safety of the air tool.
- Check that all screw fittings are seated securely,
and tighten if necessary.
- Clean the filter in the compressed air connection
at least once a week.
- It is recommended that you install a pressure
reducer with an air-water separator and lubricator
upstream of the air tool.
- If a large amount of air or oil is escaping, check the
air tool and have it maintained if necessary. (see
Section 9.)
- Avoid contact with dangerous substances that
have collected on the tool. Wear suitable personal
protective equipment and take appropriate meas-
ures to remove any dangerous substances before
maintenance.
f
8. Accessories
Use only genuine Metabo accessories.
Only use accessories that are designed for this air
tool and that fulfil the requirements and the specifi-
cations listed in these operating instructions.

Publicidad

Tabla de contenido
loading

Tabla de contenido