3. HEIGHT ADJUSTMENT ON OVEN
Remove and lay aside the lower vent grille that is taped to
the outer side panel of the oven. The grille will be fastened
to the lower front of the oven after it has been installed in
the cabinet.
There is a 1-1/2" height adjustment on these models. (see
figure 4) With this adjustment and a 1/2" trim overhang, a
unit can be installed in existing openings 48" to 50" high
(double oven) or 28-1/8" to 30-1/8" (single oven).
Figure 4
To adjust oven height:
A. Lay oven on its back. (see figure 5)
B. Remove the 6 screws that fasten the side extension
panel to the bottom sides of the oven.
C. Move each panel down to the position that increases
the oven height to fit your opening. Each position changes
oven height approximately 1/2".
D. Line up the appropriate holes in the side extension
panels and sides of the oven. Replace the 6 screws.
E. Proceed with oven installation. Return oven to upright
position.
OVEN DOOR
OVEN
BOTTOM
Figure 5
All manuals and user guides at all-guides.com
ADJUSTMENT
HOLES
EXTENSION
PANEL
MOUNTING
SCREWS
EXTENSION
PANEL
- 3 -
4. ELECTRICAL CONNECTION
It is the personal responsibility and obligation of the
customer to contact a qualified installer to assure that the
electrical installation is adequate and is in conformance
with the National Electrical Code and local code
ordinances.
ELECTRICAL GROUND IS REQUIRED
ON THIS APPLIANCE.
This appliance is equipped with copper lead wires.
connection is made to aluminum house wiring, use only
special connectors which are approved for joining copper
and aluminum wires in accordance with the National
Electrical Code and local codes and ordinances.
This appliance is manufactured with a white neutral power
supply wire and a frame connected bare ground wire.
A. If local codes permit connection of the frame
grounding conductor to the neutral (white wire),
connect the bare wire and white wire from the supply
cable of the appliance together and to the neutral (white)
wire in the junction box. Connect the remaining wires
from the supply cable, matching colors to the wires in the
junction box.
B. If used in mobile home or if local codes DO NOT
permit frame grounding to the neutral, separate the
white and bare ground wires that extend out of the end of
the supply cable of the appliance. Connect the white wire
from the supply cable to the neutral white wire in the
junction box. Connect the black wire from the supply
cable to the black wire in the junction box. Connect the
red wire from the supply cable to the red wire in the
junction box. The bare wire must now be used to ground
the appliance in accordance with local electrical codes.
Connect the bare copper ground wire to a grounded cold
water pipe* or to the grounded lead in the service panel.
Do not ground to a gas supply pipe. Do not connect to
electrical power supply until appliance is permanently
grounded. Connect the ground wire before turning on the
power. (see figure 6)
COPPER
GROUND WIRE
Figure 6
GROUNDED COLD
WATER PIPE
(REMOVE PAINT, ETC.)
TIGHTEN
NUTS FIRMLY
GROUND CLAMP
(MUST BE TIGHT
ON PIPE)
If