Door Reversal Instructions (cont)
1. Remove 2 screws (1), then pull door (4) as of arrowhead direction and then the bottom hinge (Right) (2)(Fig.A & Fig.B)
2. Remove 3 screws of right upper Hinge, then remove right upper hinge(See Fig.C)
3. Use the screws which you removed from the right side hinges to fix the left upper hinge (See Fig.D &Fig.E)
4. Rotate the door 180°, then assemble the door on the opposite side.
INSTALLATION
SPECIFICATIONS FOR BUILT-IN
• It is recommended that you do not install the unit (i.e. directly beside a wall). This is to allow the
door to have a greater then 90° opening swing. A limited door swing may lead to damaging the door gasket.
• The rough cabinet opening must be on a level floor area and at least 24" deep by 15" wide. The opening should also
have a height of at least 34 1/2".
• The electrical oulet may be positioned from within either side of the adjacent cabinetry, or the rear of the shaded
area (as shown in Fig A).
• If the electrical outlet is located inside the adjacent cabinetry, cut a 1-1/2" diameter hole to admit the power
cord. If the cabinet wall is metal, the hole edge must be covered with a bushing or grommet.
All manuals and user guides at all-guides.com
OPERATING INSTRUCTIONS
Fig.A
Fig A
3
34 1/2" from
34
/4 " from
underside of
underside
countertop
of
Electrical Access
to floor.
countertop
to floor
1
1 1/2" diam. hole
1
/2 "d iam. hol e
* If electrical outlet
* I f electrical
out -
is in adjacent
let is in adjacent
cabinetry.
cabinetry .
Cabinets
Cabinet s
square
and plumb
15"
8
square
and
plumb