Key
72 Room thermostat 1st zone (direct)
130 Hot water tank circulating pump
138 External probe
155 Hot water tank probe
300 Legionella protection circulating pump
306 Circulating pump 1st zone (direct)
I* ISPESL safety devices (When required - not supplied)
To manage sliding temperature it is necessary to purchase the external probe accessory code 013018X0
If a hot water tank probe (not supplied) is used, it is necessary to purchase the NTC probe accessory code
1KWMA11W (2 mt.) or code 043005X0 (5 mt.)
If a hot water tank thermostat (not supplied) is used, it is necessary to purchase the kit accessory code
013017X0 (to be connected in place of the Hot Water Tank Probe)
- Parameters
Each system requires a different parameterisation. Follow the access procedure given
below.
"Service Menu"
The card Service Menu is accessed by pressing the Reset button for 10 seconds.
Press the Heating buttons to select "tS", "In", "Hi" or "rE"
"tS" means Transparent Parameters Menu, "In" means Information Menu, "Hi" means
History Menu, "rE" means History Menu Reset.
Select "tS" and press the Reset button.
Check/Change parameter P02 of the "Transparent Parameters Menu" to 5.
Check/Change parameter P27 of the "Transparent Parameters Menu" to 1
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. To modify the value of a parameter just press the DHW buttons; the change will be
automatically saved.
Press the Reset button to return to the Service Menu. Press the Reset button for 10 sec-
onds to exit the card Service Menu.
"System Type Menu"
Press the Summer/Winter button for 10 seconds to access the card System Type Menu
Change parameter P.09 of the "System Type Menu" to 1.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to modify the value of a parameter: the change will be au-
tomatically saved.
Press the Summer/Winter button for 10 seconds to exit the card System Type Menu.
- Optional Functions
As well as the electrical connections of the previous figure (required for this system con-
figuration) there are options that do not require settings.
4
5
6
7
8
9
302
FUSIBILE
Esterno
L
FUSIBILE
3.15A
L
N
N
Key
139 Remote Control: it can be installed in place of 72 to manage the request of the 1st zone (direct)
301 Fault indication (voltage-free contact output): the example shows the connection of a lamp at 230Vac
302 Remote reset input (230Vac): the example shows the connection of a double-pole switch at 230Vac, allowing
the resetting of a block type fault
357 Fault indication (230Vac): the example shows the connection of a lamp at 230Vac
A direct heating circuit and a DHW circuit with diverter valve (3-wire)
- Schematic diagram
Use diverter valves with 3 wires:
- OPENING PHASE 230V
- CLOSING PHASE 230V
- NEUTRAL
with switching times (from all closed to all open) of not more than 90 seconds.
a 1st zone (direct)
b Hot water tank circuit
M Delivery
RA High Temperature Return
RB Low Temperature Return
10 11 12
13 14 15
28 29 30 31 32 33
16 17 18 19 20 21 22 23 24 25 26 27
301
139
cod. 3541A282 - Rev. 01 - 02/2013
138
M
RA
RB
- Electrical connections
After installation, carry out the necessary electrical connections as shown on the wiring
diagram.
Then configure the controller as described in the specific section.
4
5
6
7
8
L
N
32
FUSIBILE
3.15A
L
N
Key
32 Heating circulating pump
72 Room thermostat 1st zone (direct)
138 External probe
34 35 36
155 Hot water tank probe
306 Circulating pump 1st zone (direct)
348 3-way valve (3-wire)
A = OPENING PHASE
B = NEUTRAL
C = CLOSING PHASE
357
I* ISPESL safety devices (When required - not supplied)
To manage sliding temperature it is necessary to purchase the external probe accessory code 013018X0
If a hot water tank probe (not supplied) is used, it is necessary to purchase the NTC probe accessory code
1KWMA11W (2 mt.) or code 043005X0 (5 mt.)
If a hot water tank thermostat (not supplied) is used, it is necessary to purchase the kit accessory code
013017X0 (to be connected in place of the Hot Water Tank Probe)
- Parameters
Each system requires a different parameterisation. Follow the access procedure given
below.
"Service Menu"
The card Service Menu is accessed by pressing the Reset button for 10 seconds.
Press the Heating buttons to select "tS", "In", "Hi" or "rE"
"tS" means Transparent Parameters Menu, "In" means Information Menu, "Hi" means
History Menu, "rE" means History Menu Reset.
Select "tS" and press the Reset button.
Check/Change parameter P02 of the "Transparent Parameters Menu" to 6.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. To modify the value of a parameter just press the DHW buttons; the change will be
automatically saved.
Press the Reset button to return to the Service Menu. Press the Reset button for 10 sec-
onds to exit the card Service Menu.
I*
32
fig. 21
9
10 11 12
13 14 15
28 29 30 31 32 33
A
C
B
348
16 17 18 19 20 21 22 23 24 25 26 27
138
72
fig. 22
a 1st zone (direct)
b Hot water tank circuit
M Delivery
RA High Temperature Return
RB Low Temperature Return
EN
72
155
b
a
348
M
34 35 36
155
53