EXTENSION FOR INSTALLATION IN FALSE CEILING OR WALL CABINETS
E
N
G
1. Remove the small white Teflon insulation piece installed in series, which protects the nozzle.
2. Remove the nozzle with an 11 mm hex key tube (optional accessory ER KEY code 1176112)
3. Clean properly the boiler's threaded seat
4. Make a hole in the false ceiling with a diameter of 50 mm in front of the axis of the FOGGY's
nozzle.
5. Cover carefully the male thread of the extension, with a high temperature sealant to ensure a
good seal and prevent it can withdraw.
6. Slowly screw the extension to the boiler.
7. Cover carefully the thread of the nozzle with a high temperature sealant to ensure a good seal
and prevent it cannot withdraw from the extension
8. Slowly screw the nozzle extension
9. Install the insulating cylinder supplied with the kit with the two provided screws
10. Place the isolating ring cover in front of the false ceiling.
11. Make a test spray to check its proper direction (NB: as required, make small adjustments in
height acting on the extension or on the nozzle without damaging the junction)
12. Position the sticker ("WARNING BURN") near the nozzle to the ceiling.
AVS ELECTRONICS S.p.a. conserves the right to make any change at any time without notice.
PRL 10
(cod. 1176106)
Via Valsugana, 63
35010 (Padova) ITALY
Tel. 049 9698 411 / Fax. 049 9698 407
avs@avselectronics.it
www.avselectronics.com
Assistenza Tecnica: 049 9698 444
support@avselectronics.it
- 4 -
If FOGGY is installed in a false ceiling or a
wall cabinet, it is necessary to make the
nozzle of the ceiling (or cabinet) out. The
installation of the PRL 10 allows that for a
maximum distance of 10 cm.
PRL 10 is composed of an extending brass
cylinder and completed with an isolating
ring cover.