Installing the AT-EX1001SC/GM1 Multimode Extender
The AT-EX1001SC/GM1 Multimode Extender is installed and used in pairs.
The units do not support the use of any media converters in the configuration.
The pair of extenders is connected directly to the host and to each other. The
units are easy to install and do not require any software configuration or
software management.
Planning the Installation
When installing an AT-EX1001SC/GM1 Multimode Extender, do not exceed
the maximum cable distances intended for its media type. Refer to Table 2 for
a description of the standards (connectors), media, and maximum distances for
each port.
Connector
Port
Type
1
Port 1 (P1)
SC
Port 2 (P2)
SC
1. Assumes that the opposite end of the fiber cable is connected to P1 on another AT-EX1001SC/GM1
Gigabit Ethernet Mulitmode Extender.
Note
Do not use single-mode fiber on either port of the AT-EX1001SC/GM1
Multimode Extender.
6
Table 2 Media Types and Distances
Media Type
50/125 micron or 62.5/
125 micron multimode
fiber
50/125 micron
multimode fiber
62.5/125 micron
multimode fiber
MHz/km
Maximum
Rating
Distance
N/A
2 km (1.24 mi)
500
550 m (1500 ft)
400
500 m (1370 ft)
200
275 m (754 ft)
160
220 m (604 ft)