Spraycox
Spraycox II Cabinet Set-up
Pre-operations Checklist
After the machine has been properly installed and setup, perform a final check
of the Spraycox II before vaccination begins.
Before mixing vaccine, make sure the following checklist has been completed:
Examine and verify the alignment of the Spraycox II cabinet.
�
Validate the electrical supply.
�
Adjust the speed control setting.
�
Check the air supply air dryer and pressure setting.
�
Adjust the air pressure setting on the cabinet pressure regulators.
�
Check for proper alignment of the electric eye and reflector.
�
Adjust the side rails to within 1/4 inch of the sides of the chick box.
�
Vaccine Preparation and Handling
Set up the Spraycox II reservoir in
a clean laboratory setting for mixing.
Mix the proper amount of vaccine
according to the number of birds to
be vaccinated. Refrigerate Coccivac
vaccine when not in use.
Use the mixing chart supplied with
Spraycox II cabinet or the directions
provided with the Coccivac vaccine.
Only use distilled water to mix the
vaccine. To ensure proper mixing of
the vaccine, fill empty vaccine bottles
with distilled water, shake, and pour into
vaccine tank.
Daily Clean-up and Maintenance
of alcohol is detected under
the hood. Leave the alcohol in
the system for approximately
30 minutes. After 30 minutes,
drain both sides of the system.
Add one quart of distilled water
to the bottle.
Activate the purge button to
The Spraycox II cabinet must
be cleaned and thoroughly
"fire" the machine until the
sanitized with mild detergent
alcohol is completely flushed
from the system.
or alcohol 70% immediately
following vaccination.
Unplug the machine.
Disconnect the vaccine bottle
Thoroughly rinse the table and
external parts of the vaccinator
and rinse with cold, clean
tap water.
with tap water. Avoid spraying
water directly on electrical
Flush all lines and nozzles with
components.
mild detergent or alcohol 70%
Before putting the vaccinator
back into operation after a long
Re-connect the vaccine bottles.
Add one pint of alcohol 70%.
idle period, be sure to flush the
lines with distilled water.
Flush the lines until the odor
II Cabinet Operation
®
Complete instructions are in the Spraycox II Operator's Manual
®
Using a sterile syringe, add only
the prescribed amount of red
dye to the mixed vaccine.
Carefully dispose of needles
and syringes in an approved
sharps container.
Immediately move mixed vaccine
to the Spraycox II cabinet.
Before resuming vaccination,
flush the system with fresh
vaccine solution to ensure the
lines are completely free of
water and alcohol.
See the Spraycox II
Operator's Manual for
complete clean-up,
maintenance and storage
instructions.
Spraycox II Cabinet Operation
Adjust the side rails to within 1/4 inch
of the sides of a chick box.
Make sure the double dispensing block
system contains two new syringes.
Turn the Spraycox II cabinet "ON" and
depress the purge button to prime the
pump assembly.
Activate the electric eye with your
hand and observe the spray pattern.
Vaccine should be dispensed in an
even, fine spray.
Adjust air pressure settings on
compressor and cabinet until red dye
in vaccine shows proper pattern and
coverage in an empty chick box as it
passes under the nozzles.
Troubleshooting
Use the following checklist to troubleshoot a malfunctioning Spraycox II cabinet.
Make sure two new disposable syringes have
�
been installed on the double dispensing block
at the start of each day. Replace the single
syringe for the Newcastle/Infectious Bronchi-
tis vaccine each day. All syringes must be
changed as necessary during each day that
the Spraycox II Spray vaccinating cabinet is
used. At minimum, syringes must be changed
at the first employee break, and over the
lunch break.
Check for proper air pressure at the air supply
�
compressor, and at the pressure regulator.
1-800-531-0091
For Equipment Service call:
For Veterinary Technical Service call:
Coccivac and Spraycox are the property of Intervet International B.V. or affiliated companies or licensors and are protected by copyrights, trademark and other intellectual property laws.
Copyright © 2011 Intervet International B.V. All rights reserved.. SPAH-PBU-618
Check
vaccine
dosage by
placing an
empty 50 ml
graduated
cylinder
beneath
each spray nozzle. Collect a sample
as the empty box passes under
the nozzles. Combine samples into
one container. Combined, the dose
samples should measure 21ml.
Adjust air pressure until the Spraycox II
nozzle dispenses a 21 ml dose.
The Spraycox II cabinet is now ready
for vaccinating.
Make sure chicks are distributed
evenly in the boxes.
Move the chick boxes through
the vaccination process at the
appropriate speed.
Refill or refresh the Coccivac vaccine
at regular intervals.
Do not let the Spraycox II cabinet run
out of vaccine.
If the spray pattern is weak or erratic, check
�
to see that the tubing is connected properly
and not crimped, pinched or damaged.
Check the spray nozzles for clogs and
�
overall cleanliness.
Make sure the speed regulator is properly
�
adjusted.
Inspect the electric eye. Make sure it is
�
properly aligned, and that its wiring is
properly connected.
Ensure that the side rails are properly
�
adjusted to 1/4 inch clearance.