12 INSTALLATION
F
E
D
B
I
H
A
B
C
D
2
E
2
F
2
G
H
2
I
J
K
L
2
NOTE
• For closet installation, with a door, minimum
ventilation openings in the top and bottom of
the door are required. Louvered doors with
equivalent ventilation openings are acceptable.
• Minimum vent opening for built-in installation is
2
31.5 sq. in. (200 cm
Closet Ventilation Requirements
Closets with doors must have both an upper and
lower vent to prevent heat and moisture build-up
in the closet.
J
G
K
L
L
Dimensions
inch
mm
25 1/2
650 mm
2
18
2
455 mm
2
10
2
250
74 3/8
2
1889
74 1/8
1875
2
15 3/4
400
2
2
50
2
2
24 7/8
2
630
2
19
2
485
2
2
2
50
1
25
2
2
1 3/16
30
2
.)
One example shown uses vent grilles in the door.
Upper vent opening with a minimum opening
a
of 48 sq. in. (310 cm
lower than 6 ft. (185 cm) above the floor.
Lower vent opening with a minimum opening
b
of 24 sq. in. (155 cm
more than one foot above the floor.
Ambient Temperature
• Temperature must be between 50 ℉ (10 °C) and
95 ℉ (35 °C).
• If the ambient temperature is too low or high,
performance may be affected.
• Do not install in direct sunlight or where the
temperature may fall below 32 ℉ (0 °C).
Electrical Connection
• Do not use an extension cord or 2-outlet
adapter.
• Do not overload the outlet with more than one
appliance.
• Connect the appliance to an earthed socket in
accordance with current wiring regulations.
• The appliance must be positioned close to
outlets and the plug should be easily accessible.
WARNING
• The power cord must be plugged into an
appropriate outlet that is installed and
grounded/earthed in accordance with all local
codes and ordinances.
7.6 cm
7.6 cm
7.6 cm
7.6 cm
2
) must be installed no
2
) must be installed no