PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE MODULES
INSTALLATION MANUAL
FOR NA-FxxxGK SERIES

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Sharp NA-F GK Serie

  • Página 1 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE MODULES INSTALLATION MANUAL FOR NA-FxxxGK SERIES...
  • Página 2 Sharp kontor, der er oplistet på Sharp Solar Uautoriserede reservedele kan resultere i brand, elektrisk stød hjemmesiden : URL : http://www.sharp-world.com/solar eller andre farer.
  • Página 3 Niet-goedgekeurde Sharp-kantoor. De lijst van kantoren vindt u op de Sharp Solar vervangingen kunnen brand, een elektrisch schok of andere website : URL: http://www.sharp-world.com/solar gevaren veroorzaken.
  • Página 4 Muna mbíonn do chóip phearsanta féin agat, sonraithe ag an déantóir leis na sonraí céanna is a bhí ag na déan teagmháil le do theicneoir suiteála nó le h-oifig áitiúil Sharp páirteanna bunúsacha. Muna n-úsáidtear na páirteanna cearta tá...
  • Página 5 Sharp più vicino, indicato al sito Internet Sharp 11. Rivolgersi all’ufficio locale responsabile per la sicurezza e Solar: URL : http://www.sharp-world.com/solar l’edilizia per quanto riguarda i permessi necessari e le relative...
  • Página 6 INSTALAÇÃO -MÓDULO FOTOVOLTAICO-. Se não possuir a fabricante com as mesmas características das peças originais. sua cópia, contacte o seu instalador ou os serviços Sharp locais Substituições não autorizadas poderão resultar em fogo, choque listados no site Sharp Solar : URL : eléctrico ou outros perigos.
  • Página 7 Los local Sharp listada en el sitio web de Sharp Solar : URL : reemplazos no autorizados podrían resultar en incendios, http://www.sharp-world.com/solar...
  • Página 8: Kullanim Kilavuzu

    özelliklere sahip lütfen kurulum personelinize veya Sharp Solar web sitesinde yedek parçaları kullandığından emin olunuz. Yetkili olmayan bir kayıtlı bulunan yerel Sharp ofisine başvurunuz : URL : değiştirme, yangına, elektrik çarpmasına veya benzeri başka http://www.sharp-world.com/solar tehlikelere neden olabilir.
  • Página 9: General Information

    SHARP for any infringement of patents or other rights of third parties building/fire codes. that may result from use of PV module. SHARP reserves the right to 6. In the case that the PV modules are non-integral type, the module make changes to the product, specifications or installation manual is to be mounted over a fire resistant roof.
  • Página 10: Site Selection

    PV module and cause corrosion. 12. Do not touch the PV module with bare hands. The frame of PV Frame module has sharp edges and may cause injury. 13. Do not drop PV module or allow objects to fall down on the PV module.
  • Página 11 (*) If you are planning to use the PV modules where the salt water damage The modules should be grounded to the same electrical point as may be possible, please consult with SHARP local agent first to determine an described below.
  • Página 12 11. MAINTENANCE water when there is a danger of frost and strong temperature differences between the module, water and air. Hard water used as a The modules are designed for long life and require very little cleaning agent should be decalcified beforehand in order to avoid maintenance.
  • Página 13 INSTALLATION MANUAL - PHOTOVOLTAIC MODULES- NA-F115GK, NA-F121GK, NA-F128GK, NA-F135GK 1. INSTALLATION The mounting method has been verified by SHARP and NOT CERTIFIED by a third party organization. Please review the descriptions and drawings carefully; not mounting the modules according to this method may void your guaranty. This module satisfies the requirement of mechanical load test at 2400Pa in accordance with IEC61646.
  • Página 14: Module Configuration

    Clip 5mm Min. Catch Width Frame 10mm Min. Rail Support Width Prohibited Figure 3 Figure 4 Caution The mounting methods shown in Fig. 4 are prohibited. 2. ELECTRICAL INSTALLATION INSTRUCTION Cable characteristics Size: 2.5mm Type: CE cable Temperature rating of conductor: -40~90°C Module configuration # Maximum series configuration: please refer to Table 1 (This value is calculated under the condition of Voc at -40°C.)
  • Página 15 3. WARNING Do not stand or step on the PV module (Frame, Glass, Film and Terminal box). 4-1. ELECTRICAL OUTPUT (for NA-F115GK, NA-F121GK, NA-F128GK) Rated electrical characteristics of Isc and Voc are within ±10 percent of the indicated values and +10/-5 percent of Pmax under STC (standard test conditions) (irradiance of 1000 W/m , AM 1.5 spectrum, and a cell temperature of 25 °C (77°F).