3.

Parts and description

UK
1
Valve coil.
2
Appliance plug for electrical connection.
3
Hose connection (screw connection) on the inlet side (for hose 4 / 6 mm).
4
Hose connection (screw connection) on the outlet side (for hose 4 / 6 mm).
5
Hexagon nut fixed to valve core.
6
O-ring seal of valve core.
7
Coupling and cable for connection 12 V DC.
8
Universal power supply unit.
9
Plug 12 V DC.
10 External thread (1/8") of valve core.
11 Hose connection (screw connection) of pressure regulator.
12 Internal thread (1/8") of pressure regulator.
4.

Installation

There are two installation methods:
4.1
Connection to the CO
hose (4 / 6 mm)
2
· Cut the CO
hose close to the pressure regulator.
2
· Attach the cut hose ends to the hose screw connections (3, 4) of the solenoid valve. Note the flow direction of the valve (arrow on valve body (1)).
· First plug the power supply unit of the solenoid valve into a socket that is controlled by a time switch (not included), e.g. for the aquarium lighting.
Connect the 12 V cable of the power supply unit to the cable of the solenoid valve.
4.2
Direct connection to a pressure regulator (e. g. JBL PROFLORA CO
JBL PROFLORA CO

REGULATOR AVANCED)

2
· Completely disconnect the hose connection on the inlet side of the solenoid valve (3).
· Also disconnect the hose connection on the pressure regulator.
· Holding the valve by the valve body (1), turn the valve core with its external thread (10) into the internal thread of the pressure regulator. In doing
so, turn the valve core by its fixed hexagonal nut (5).
· The firmly integrated O-ring (6) at the valve core automatically seals between the valve and the pressure regulator.
· Position the valve as required.
· Connect the CO
hose of your CO
system to the hose screw connection at the outlet (4).
2
2
· First plug the power supply unit of the solenoid valve into a socket that is controlled by a time switch (not included), e.g. for the aquarium lighting.
Connect the 12 V cable of the power supply unit to the cable of the solenoid valve.
5.

Technical data:

Voltage: 12 V DC
Power input: 2 W
Outlet hose screw connection: for hose 4/6 mm
Input thread: 1/8"
Closed when currentless (NC)
Power supply unit:
Primary: 100 – 240 V AC; 47 – 60 Hz; 0.25 A
Secondary: 12 V DC; 0.3 A; 3.6 W
8
6.
In addition to the legal claims of the customer against the seller the guarantee covers the delivery of goods which are free of defects and does not
affect the statutory claims for defects in accordance with § 437 BGB.
We, JBL GmbH & Co. KG Dieselstr. 3, 67141 Neuhofen, Germany offer the end user a guarantee of 2 years from the date of purchase for functionality
and absence of defects for the products listed below.
Furthermore we offer the end user, after a successful product registration for the device within the statutory warrantee period, under www.jbl.de/?-
mod=productsregistration&func=landing&lang=en&country=gb, an extended 4 years guarantee from the date of purchase.
JBL PROFLORA CO
Wear parts, such as seal rings, are excluded from the guarantee.
The guarantee includes the repair at our discretion by replacement (free delivery of a comparable product) or its overhaul in accordance with the
technical requirements.
The remaining period of the original guarantee period applies for the part to be overhauled or replaced under this guarantee.
The guarantee does not include the compensation of direct or indirect consequential damages.
The guarantee only applies on sales to customers within the European Union.
The guarantee is void, if the product was not correctly installed, maintained or cleaned, intentionally damaged or modified in any way not according
to the intended purpose by the customer or third parties.
Please contact your specialist retailer during the guarantee period by presenting a valid purchase receipt or contact us under
www.jbl.de/?mod=support&func=execute&lang=en&country=gb
JBL GmbH & Co. KG
Dieselstr. 3
REGULATOR BASIC or
2
D-67141 Neuhofen
Germany

Manufacturer Guarantee

VALVE
2
UK
9

Publicidad

loading