Troubleshooting

Problem
The power indicator of the
transmitter does not turn
on.
Even if I block the infrared
light, the alarm indicator of
the receiver does not turn
on.
The alarm indicator of the
receiver will not turn off.
The alarm sounds
intermittently.
Scanning Type
4-channel adjustment
If you want to install multiple sensors in different ways, use the channel setting function to avoid confusion between sensors.
<1 CH>
<2 CH>
Z6806119901A-SIA-0100Q,0200Q.ind12 12
Z6806119901A-SIA-0100Q,0200Q.ind12 12
All manuals and user guides at all-guides.com
Reason
1.
Make sure the power is applied.
2.
Check whether there is any loose contact,
disconnection or short-circuited.
1.
Make sure the power is applied.
2.
Check whether there is any loose contact,
disconnection or short-circuited.
3.
Check whether the receiver takes IR signal
input refl ected by any object.
4.
Check whether 2 optical signal inputs are
blocked simultaneously.
1.
Check whether the optical axis is dislocated.
2.
Check whether there is obstruction between
the transceiver and receiver.
3.
Check whether the transceiver/receiver
cover is contaminated.
1.
Check whether the wiring is correct.
2.
Check whether the voltage of power source
is stable.
3.
Check whether there is obstruction between
the transceiver and receiver.
4.
Check whether there is strong power line or
wiring near the transceiver/receiver.
5.
Check whether the transceiver/receiver is
attached fi rmly.
6.
Check whether the optical axis is dislocated.
7.
Check whether the transceiver/receiver
cover is contaminated.
8.
Animals such as birds and cats may
interrupt optical signal.
<3 CH>
<4 CH>
English _12
1.
Apply the power.
2.
Check if the cables are properly connected.
1.
Turn on the sensor.
2.
Check if the cables are properly connected.
3.
Remove the interruption object, or change
the installation site or the orientation of the
optical axis.
4.
Block two light sources simultaneously.
1.
Adjust the optical axis as necessary.
2.
Remove the obstacle.
3.
Wipe out the impurities with a soft cloth.
1.
Check the connection status again.
2.
Regulate the power voltage.
3.
Remove the obstacle.
4.
Change the wiring path.
5.
Secure the pole or support.
6.
Adjust the optical axis as necessary again.
7.
Wipe out the impurities with a soft cloth.
8.
Set the response time longer.