How to Install Your CO Alarm cont.
11. Firmly PRESS AND RELEASE THE
RESET/TEST button. See Figure 7. The
alarm should sound a short tone. The amber
SERVICE light will turn on, and the CO alarm
will go through its test cycle. The red LED
will flash, and the alarm will beep four times
followed by 5 seconds of silence and then
repeat the cycle. After the test cycle, amber
SERVICE light will turn off, and the green
POWER light will remain lighted which means
that the CO alarm is operating properly.
12. If the alarm is interconnected to other CO alarms, press and hold the Reset/Test
button until the red light turns on. Other interconnected alarms will also beep four
times followed by 5 seconds of silence. The red ALARM light on other alarms will
not light during this test.
13. Two self-adhesive labels have been provided with instructions indicating what to do
if the alarm sounds. Add the phone numbers of your emergency services provider
and a qualified technician to each label. Place one of the labels in a visible area next
to the alarm, and place the other label near a source of fresh air which will be used
as a gathering place if the alarm sounds.

How to Operate Your CO Alarm

This carbon monoxide alarm has been evaluated by UL and meets the applicable
UL standards and requirements.
This CO alarm has a three light and sound alarm
system:
On
Green colored indicator constantly ON indicates unit is receiving AC
(Power on/ operating)
power.
Service
Amber colored indicator flashing and alarm horn beeping every
(Problem with Alarm)
thirty seconds indicates unit fault. Press and release the Test/Reset
button. If the alarm returns to displaying the fault signal, the CO
alarm is not operating properly. REPLACE THE CO ALARM IMMEDI-
ATELY. SEE THE WARRANTY INFORMATION AT THE END OF THIS
MANUAL.
Alarm
Red colored indicator flashes and alarm horn sounds four fast
(Dangerous CO levels)
beeps and then is quiet for 5 seconds.
When the CO concentration builds to a level that is equal to 70 ppm or greater for
the duration identified within the standard, the following will occur:
• The ALARM light and sound signals will activate. See the "What To Do If Your
Alarm Sounds" section of this manual for important action steps to be taken.
• If you wish to press the Test/Reset button during this time, the alarm will become
quiet for approximately four minutes. The ALARM signals will be reenergized within
4 minutes from the time the reset button is pressed if the concentration of carbon
monoxide surrounding the alarm remains at 70 ppm or greater.
• The alarm will remain silent if the CO concentration has decreased below the
alarm level of the standard. See "What To Do If Your Alarm Sounds" section of
this manual for important action steps to be taken.
• The alarm will continue for as long as the condition exists.
The alarm will not permanently end its alarm mode until the concentration of CO
has been reduced to a safe level.
Page 5
PRESS
IN, HOLD,
AND
RELEASE
TO
RESET
AND/OR
TEST.
CARBON MONOXIDE ALARM
ON
5
FIGURE 7
:
SERVICE
ALARM
M
T
F
A
OVE
O
RESH
IR