Note
The status LED flashes to indicate:
connection in progress
connection problem (check that the MASTER/SLAVE devices are switched on. In the case
of wireless connection, try to remove pairings between MASTER and SLAVE, pressing the
[ALT] + [WIRELESS RESET] keys and then follow the pairing procedure again).

3.4. TEST function

A "TEST" function is available to check correct functioning of the FA-15 device.
To activate it, simply press the keys [ALT] + [TEST] on the remote control/app.
Each time these keys are pressed, the device will perform one step of the following sequence:
switching on of all views on the display
switching on of indicators (red, green, white, yellow) alternately with all other views
keeping certain views switched on, it will launch the red, green and white indicators in sequence
(demo mode)
switching on in sequence of various views
test of weapons circuit: if all seven rear sockets are short-circuited (weapons + piste), the device
emits a continuous tone to confirm correct functioning of the weapon control circuits.
To deactivate the "TEST" function, press the [ON-OFF] key on the remote control/app.
4. M AINTEN A NCE

4.1. Outer cleaning

Clean using a clean lint-free cloth to remove dust.
DO NOT
use abrasive chemical products, petrol, trichloroethylene, alcohol or steam-cleaning tools.

4.2. Troubleshooting

All maintenance, repairs and checks on the scoreboard MUST ONLY be performed by qualified
technicians.
Error
1. When the power is
connected, the display
remains switched off
2. The status LED flashes
BLUE.
FAV E RO E L EC T RO NIC S
Solution
(a) Check the power supply unit and power connections.
(b) If using a power bank, check the level of charge and recharge if
required.
(c) Try using another USB power supply unit.
The status LED is blue when the device is in "MASTER" operating mode and
flashes if at least one SLAVE device paired is unable to connect wirelessly:
(a) leave the "Master" mode by pressing the [ALT] + [WIRELESS RESET]
keys on the remote control paired to the MASTER device. Now try and
pair the "SLAVE" devices in question again (see paragraph "3.3. Devices
in MASTER - SLAVE mode").