RS 578-474 Instrucciones De Instalación página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

V8157
5
B
C
(561-XXX)
Type C
A. See table
B. Mains output
C. Transformer
D. S.E.L.V. output
E. Fuse
F. Fused splitter
RS stock no. 561-842
Typ C
A. Siehe Tabelle
B. Netzausgang
C. Transformator
D. SELV-Ausgang
E. Sicherung
F. Sicherungsverteiler
RS Best.-Nr. 561-842
Tipo C
A. Consulte la tabla
B. Salida de red
C. Transformador
D. Salida de CTES
E. Fusible
F. Separador provisto de
fusibles
C—digo RS
561-842
Type C
A. Voir le tableau
B. EntrŽe secteur
C. Transformateur
D. Sortie S.E.L.V.
E. Fusible
F. Diviseur ˆ fusible
code commande
RS 561-842
578-474, 578-430, 578-446, 578-452, 578-468,
561-791, 561-808, 561-814, 561-820, 561-836
Notes
Warning: Isolate the mains supply before commencing installation or
undertaking any other work on the transformers.
Installations should be in accordance with the requirements of the
current edition of the IEE wiring regulations together with any other
relevant regulations (e.g. building, fire, etc.) applicable to the
site/installation.
2
A
20 x 5mm
20W
2.0A
35W
3.0A
50W
5.0A
E
E
E
E
D
F
Tipo C
A. Vedere tabella
B. Uscita rete elettrica
C. Trasformatore
D. Uscita S.E.L.V.
E. Fusibile
F. Divisore a fusibile
Codice RS 561-842
Type C
DK
A. Se tabel
B. Netudgang
C. Transformer
D. S.E.L.V. udgang
E. Sikring
F. Fordeler med sikring
RS varenr. 561-842.
NL
Optie C
A. Zie tabel
B. Voedingsuitgang
C. Transformator
D. S.E.L.V.-uitgang
E. Zekering
F. Splitter met zekering
RS-voorraadnummer
561-842
Type C
SE
A. Se tabell
B. NŠtanslutning
C. Transformator
D. S.E.L.V. utstršm
E. SŠkring
F. SŠkrad fšrdelare
RSÕ Largernummer
561-842
RS Stock No.
The transformers should be sited in a ventilated area free of insulation
materials (mineral wool or similar) where the ambient temperature
during operation will not exceed the maximum temperature rating for
the transformer.
Switches and dimmers should be connected into the input / primary
circuit.
All of these transformers have an auto-resetting thermal cutout device
protecting the transformer in case of overload. The type C also has a
primary fuse.
The type C - Under output short circuit conditions very high currents will
flow therefore current limiting device\s must be used in the output
circuit and use output cable capable of withstanding the high
current/temperature.
Type B - Auto-reset current and temperature sensitive circuit
incorperated into each output circuit.
Dimming
Dimmers used with these 'wound' transformers must be of types
suitable for inductive loads.
Ratings
Input voltage: ____________________________230Vac ± 10% 50Hz
Output voltage:__________11.4Vac Nom. on full load with 230V input
Output load: Type A & C ____________________________80% min-
Type B ________________________________50VA (W) per output,
unused outputs may be left disconnected with no
Thermal: __________________All models - Max. operating ambient
Fuses:
561-791 561-808
2.0AT
3.15AT
All fuses must be of; anti surge, slowblow or delayed type.
Acoustic: ________________________All models - Very low audible
Circuit breakers
To avoid nuisance tripping of breakers during the switch on of the lights
use breakers of types suitable for inductive loads, e.g. Type 3 (C) or
Type 4 (D)
Output voltage drop
The following cable lengths give approx. 0.25V drop with multi-core
cable, copper conductors (Ref. IEE Wiring Reg. 16th Ed. 1991 - Table
4D2B)
Current calculated on the basis of 12Vdc or 12V r.m.s. a.c. 50Hz with
unity power factor.
These installation instructions should be kept for future reference by
the person responsible for the electrical installation concerned.
LOAD
20W
35W
50W
75W 100W
CSA
(1.7A) (2.9A) (4.2A) (6.3A) (8.3A) (12.5A) (16.7A) (20.8A) (25A) (33.3A)
2
1.00mm
3.2m
1.7m
1.2m
0.7m
2
1.50mm
5m
2.7m
2m
1.2m
2
2.50mm
8m
4.7m
3.2m
2m
2
4.00mm
13.2m 7.7m
5.2m
3.5m
2
6.00mm
20m 11.7m
8m
5.2m
These instructions are intended for installation guidance, they do not
indicate suitability for application, this should be determined by the
installation designer from the various product/ equipment/ material
specification.
RS Components shall not be liable for any liability or loss of any nature (howsoever
caused and whether or not due to RS ComponentsÕ negligence) which may result
from the use of any information provided in RS technical literature.
100% max. of transformer rating.
detrimental effects. Outputs cannot
be connected in series or parallel.
temperature (ta) 40¡C
561-814
561-820 561-836
5.0AT
5.0AT
6.3AT
noise under normal conditions this may
increase slightly when phase control
dimmers are used therefore avoid
mounting transformers onto surfaces
which could act as a sounding board
150W
200W
250W 300W 400W
0.5m
...
...
...
1m
0.5m
...
...
1.5m
1m
0.7m
...
2.5m
1.7m
1.2m
1m
0.7m
4m
2.5m
2m
1.5m
1.7m
...
...
...
...
...
...
...
1m