Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

MODEL QTN130LE
FAN / LIGHT / NIGHT LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with
the homeowner.
All manuals and user guides at all-guides.com
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
The fan, light, and night light can be operated separately. Use a
3-function wall control. Do not use a dimmer switch to operate
the light. See "Connect Wiring" for details.
WARRANTY
NUTONE THREE YEAR LIMITED WARRANTY
NuTone warrants to the original consumer purchaser of its products that such
products will be free from defects in materials or workmanship for a period
of three years from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE.
During this three-year period, NuTone will, at its option, repair or replace,
without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP START-
ERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS,
DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR
DUCTING. This warranty does not cover (a) normal maintenance and service
or (b) any products or parts which have been subject to misuse, negligence,
accident, improper maintenance or repair (other than by NuTone), faulty
installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.
NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NU-
TONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE
FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING
OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or conse-
quential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify NuTone at the address or
telephone number below, (b) give the model number and part identification
and (c) describe the nature of any defect in the product or part. At the time
of requesting warranty service, you must present evidence of the original
purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.broan.com 800-558-1711
Register your product online at: www.nutone.com/register
MODEL QTN130LE
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para NuTone QTN130LE

  • Página 1 6. Ducted fans must always be vented to the outdoors. normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP START- 7. Acceptable for use over a tub or shower when connected to ERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, a GFCI (Ground Fault Circuit Interrupter) - protected branch DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR circuit. DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, 8. This unit must be grounded. accident, improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the three-year period as specified for the express warranty. Some states do not allow limitation on how CAUTION long an implied warranty lasts, so the above limitation may not apply to you. NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NU- TONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE 1. For general ventilating use only. Do not use to exhaust hazard- REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING ous or explosive materials and vapors.
  • Página 2: Typical Installations

    All manuals and user guides at all-guides.com MODEL QTN130LE Page 2 TYPICAL INSTALLATIONS PLAN THE INSTALLATION COOKING AREA Do not install above or inside this area. Housing mounted to joists. NOT FOR USE IN Cooking A COOKING AREA. Equipment Floor...
  • Página 3 All manuals and user guides at all-guides.com MODEL QTN130LE Page 3 INSTALL HOUSING & DUCT CONNECT WIRING 1. Bend housing tabs. Use a pliers to bend housing TABS out to 90 TABS 2. Mount SPACER housing to (use for mounting to I-Joist) joist. Hold housing in place so that the housing tabs contact the bottom of the joist. The hous- ing mounts with I-JOIST four (4) screws or nails. Screw or...
  • Página 4: Service Parts

    All manuals and user guides at all-guides.com MODEL QTN130LE Page 4 8. Push grille against ceiling. 9. Remove light lens. Carefully insert a small flat-blade screwdriver between grille and lens. Pry lens out. SERVICE NOTE 10. Install light To remove bulbs. Blower Assembly: Purchase (2) 18W Unplug motor. (max.), type GU24 Remove fluorescent lamps with thumbscrew (11) M.O.L. (maximum...
  • Página 5: Limpieza Y Mantenimiento

    All manuals and user guides at all-guides.com MODELO QTN130LE Página 5 MODELO QTN130LE VENTILADOR / LÁMPARA / LÁMPARA DE NOCHE LEA Y CONSERVE ESTAS INSTRUCCIONES LIMPIEZA Y MANTENIMIENTO ADVERTENCIA Para lograr un funcionamiento silencioso y eficiente, como también larga PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS vida y una apariencia atractiva, baje o retire la rejilla y aspire el interior ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LAS de la unidad con el accesorio del cepillo para sacudir polvo.
  • Página 6: Instalaciones Típicas

    All manuals and user guides at all-guides.com MODELO QTN130LE Página 6 INSTALACIONES TÍPICAS PLANIFICACIÓN DE LA INSTALACIÓN ÁREA QUE COCINA No instale sobre o dentro de esta área. Montaje de cubierta en viguetas. NO PARA EL USO EN UN Equipo ÁREA QUE COCINA.
  • Página 7: Instale La Cubierta

    All manuals and user guides at all-guides.com MODELO QTN130LE Página 7 CONEXIÓN ELÉCTRICA INSTALE LA CUBIERTA Y EL CONDUCTO 1. Doble las lengüetas de la cubierta. Con un alicate, doble las LENGÜETAS de la LENGÜETAS cubierta a 90°. 2. Monte la SEPARADOR (se usa cubierta en para el montaje a la vigueta “I”) la vigueta.
  • Página 8: Piezas De Repuesto

    97016591 Conjunto del ventilador 97018428 Conjunto de la rejilla (incluyen las piezas de las claves n. 8 y 9) 99140199 Resorte de la rejilla (se requieren 2) 99111512 Lente 97018014 Separador (provisto 2) 99420665 Tornillo de mariposa n. 8-18 x 0.375 Reductor de conducto - 6 a 4 pulg. Lámpara fluorescente, GU24, 18W 99271381 (se requieren 2) Las piezas de recambio se pueden ahora pedir en * No incluida - se vende por separado. nuestro Web site. Visítenos Al hacer el pedido de una pieza de servicio se debe especificar por favor en www.nutone.com 99044680C el número de la pieza (no el número de la clave).