Electrical Scheme
5 - Electrical Scheme
FUSES:
F1 - LOW BLOWER 1 - 20A
F2 - HIGH BLOWER 1 - 30A
F3 - FAN 1 - 20A
F4 - FAN 3 - 20A
F5 - LOW BLOWER 2 - 20A
F7 - HIGH BLOWER 2 - 30A
F8 - CLUTCH - 10A
F9 - FAN 2 - 20A
RELAYS:
RL1 - HIGH BLOWER 1
RL2 - LOW BLOWER 1
RL3 - FAN 1
RL4 - FAN 3
RL5 - EVAPORADOR V. BAIXA 2
RL6 - HIGH BLOWER 2
RL7 - CLUTCH
RL8 - FAN 2
MAXIMUM CURRENTS CN1:
PINO 2 - MOTOR FAN. 1 - 20A@14VDC
PINO 3 - MOTOR LOW BLOWER 1 - 20A@14VDC
PINO 6 - EXIT TO AIR BARRIER - 0,5A@14VDC
PINO 8 - MOTOR HIGH BLOWER 1 - 30A@14VDC
MAXIMUM CURRENTS CN2:
PINO 2 - MOTOR FAN 2 - 20A@14VDC
PINO 3 - CLUTCH - 10A
PINO 7 - MOTOR HIGH BLOWER 2 - 30A@14VDC
PINO 8 - MOTOR LOW BLOWER 2 - 20A@14VDC
PINO 9 - MOTOR FAN 3 - 20A@14VDC
PS.: Because this is an electrical control equipment with high
commuting current, it is very important to be installed at a
vented, open space, far from fuel / flammable material
pipelines under the risk of fire / explosion.
This equipment is not protected against water. Jets or
splashes of water may damage it.
The power screw must be tighten up so that the risk of
fire because of a bad electrical contact may be avoied.
CN1
Connector
Ref. AMP : 880125-0
Pins
Ref. AMP : 880684-4
1 - TURNS ON FANS
2 - FAN. 1
3 - LOW BLOWER 1
4 - TURNS ON BLOWER HIGH
5 - TURNS ON BLOWER LOW
6 - EXIT TO AIR BARRIER
7 - N.C.
8 - BLOWER HIGH 1
9 - D+
CN2
Connector
Ref. AMP : 880125-0
Pins
1 - N.C.
Ref. AMP : 880684-4
2 - FAN 2
3 - CLUTCH
4 - GND
5 - + 12V AFTER IGNITION
6 - N.C.
7 - BLOWER HIGH 2
8 - BLOWER LOW 2
9 - FAN 3
PS.: When connecting pin 5CN2 (+12V battery after
ignition),use a 1A external pin.
Este desenho é de propriedade de SPHEROS CLIMATIZAÇÃO do BRASIL, e é fornecido com objetivo
estritamente confidencial, não devendo ser divulgado para terceiros, reproduzido ou usado com
propósito de fabricação sem expressa e escrita permissão da companhia.
DENOMINAÇÃO:
GL-T043
CODIGO DESENHO:
DATA:
25/04/07
GL-T043
35