Cleaning, Maintenance And Storage - Conrad Atlantik Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
4.
Please make sure that the end of the water tube is always lower
than the water connection in the air-conditioner, so that the water
can drain freely and safely out of the tube (27).
5.
Check regularly that the water tube (27) is fitted securely and
tightly, and that it is not blocked. Empty the external container
regularly. Overflowing water can damage objects and floor
coverings, or cause an electric shock.
FITTING THE WASTE-AIR TUBE
("COOL" operational mode)
The air-conditioner offers two ways of fitting the waste-air tube (10).
The waste-air tube can be pulled out to a length of 50 – 200 cm.
However, for best results the length should be kept to a minimum.
IMPORTANT: Do not stretch or buckle the waste-air tube (Fig. 6).
Temporary installation
1.
Fit the waste-air tube (10) onto the connection to the waste-air
vent (12) at the back of the air-conditioner. First fit the left side of
the waste-air tube, then the right side. Push the waste-air tube
(10) down and make sure that the waste-air tube (10) is fitted
securely.
2.
Check that the reducing duct (11) is attached securely to the
other end of the waste-air tube (10).
3.
Put the waste-air tube (10) with the fitted reducing duct (11)
through an open window to outdoors. Make sure that the
waste-air tube (10) and reducing duct (11) are at a height of at
least 30 cm up to a maximum of 120 cm, measured from the
surface on which the air-conditioner is standing. (Fig. 5 + 6).
4.
If you do not wish to use the air-conditioner, remove the waste-air
tube from its window position.
Permanent installation
1.
Fit the waste-air tube (10) onto the connection on the waste-air
vent (12) at the back of the air-conditioner. First fit the left side of
the waste-air tube, then the right side. Push the waste-air tube
(10) down and make sure that the waste-air tube (10) is fitted
securely.
2.
Drill a hole with a diameter of 125mm through an outside wall.
Make sure that the hole is at a height at least 30 cm up to a
maximum of 120 cm, measured from the surface on which the
air-conditioner is standing (Fig. 6).
3.
Push the adapter (24) into the hole and fix it to the wall with the
enclosed 4 plugs and screws.
4.
Take the cap off the adapter (24) and push the waste-air tube
(10) into the adapter without the reducing duct (11).
5.
If you do not wish to use the air-conditioner, take the waste-air
tube (10) out of the adapter (24) and close the adapter with the
cap.
WINDOW-FITTING TRACK
The window-fitting track can be fitted both horizontally and vertically
in most sash windows.. See (Fig. 7) für minimum und maximum
window openings.
INSTRUCTIONS FOR USE
HCL-57E – Cooling, Drying, Air-conditioning, Timer function
1.
Check that the power switch (13) is in the OFF position. Plug into
a power socket. Do not touch the power cable with wet hands.
2.
Make sure that the air-intake vent (8) and waste-air vent (2) are
open and that the waste-air tube for the „COOL" mode is fitted.
3.
Press the power switch (13), to switch on the air-conditioner.
4.
Press the operational key „MODE" (15) for the desired mode
•COOL
•DRY
•FAN
The corresponding control light comes on.
All manuals and user guides at all-guides.com
ENGLISH
5.
6.
7.
8.

CLEANING, MAINTENANCE AND STORAGE

We recommend you to clean the appliance frequently. So as not to
interfer with the functioning of the air-conditioner, please follow the
instructions for cleaning, maintenance and storage.
Daily cleaning
1.
2.
3.
4.
5.
5
COOL operational mode
Press the temperature keys „TEMP"(19) „UP" or „DOWN", to
select the required room temperature between 17 °C and 30 °C.
The selected temperature appears on the display (20). Press the
fan-speed key „FAN" (17), to select the fan speed - „HIGH" –
„MED" (medium) – „LOW". The corresponding control light (18)
comes on. Make sure that the waste-air tube (10) is fitted
according to the instructions under " fitting waste-air tube".When
you switch this mode off, wait for at least 3 minutes before
switching this mode back on, to avoid damaging the compressor.
DRY operational mode
In this mode the air-conditioner runs at a pre-set speed which
cannot be changed. The temperature cannot be selected on the
display (1). Keep windows and doors closed to achieve optimal
dryness. The waste-air tube (10) must not be connected to
outdoors. When you switch off this mode, wait at least 3 minutes
before switching this mode back on, in order to avoid damaging
the compressor.
FAN (air-conditioning) mode
Press the fan-speed key „FAN" (17), to select the fan speed
„HIGH" – „MED" (medium) – „LOW". The corresponding
control light (18) comes on. The temperature cannot be selected.
The waste-air tube (10) must not be connected to outdoors.
Timer function
By pressing the timer keys (22) „TIMER ON" and „TIMER
OFF"you can choose a time for the air-conditioner to switch on
and off automatically (between 0 and 24 hours). The number on
the setting is not the actual time of day, but corresponds to the
period of time within which the air-conditioner automatically
switches on and off. These functions can be programmed
separately. The corresponding timer-control lights on the
air-conditioner display come on. Press the power switch (13) to
cancel the timer programming.
The air-conditioner switches itself on automatically after the time
period programmed with the„TIMER ON" key has elapsed, and
the control light goes off. The air-conditioner switches itself off
automatically after the time period programmed with the„TIMER
OFF" key has elapsed, and the control light goes off. Renewed
pressing of the timer keys (22) changes the pre-programmed
times. If there is break in the electricity supply (e.g. during a
power cut) the programming is not lost.
Automatic swing of the air-vent grating
Press the„SWING" key (7). The air vent grating swings
automatically from left to right. Press the key again to stop the
swing.
Water tank control light
When the water tank (5) is full, the control light (14) comes on.
Follow the instructions described in the section on „water
disposal".
Before moving or storing the air-conditioner, press the power
switch (13) to the OFF position und unplug from the power
source.
Before you start cleaning the air-conditioner, press the power
switch (13) to the OFF position and unplug the appliance.
Empty the water tank (5) as described in the section on "water
disposal".
Rinse the water tank (5) carefully with luke-warm water.
Clean the water tank (5) with a soft, damp cloth.
To restart the air-conditioner follow the "instructions for use".

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hcl-57e

Tabla de contenido