IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and
instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, and building materials. Do
not install in areas subject to combustible vapors or gases. Before wiring to power supply and during servicing, turn off power at
fuse or circuit breaker. All servicing must be performed by qualified service personnel. Product must be grounded to
avoid potential electric shock or other potential hazard. Product must be mounted in locations and in a manner
consistent with its intended use, and in compliance with the National Electrical Code and local codes. The use of
accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe
condition. Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Do not allow items
such as drapes, curtains, screens or the like to come into contact with the product or to block light from the product, as this may
cause an unsafe condition.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
WARNING – This product contains chemicals known to the State of California to cause cancer, birth defects and/or other
reproductive harm. Thoroughly wash your hands after installing, handling, cleaning, or otherwise touching this product.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
1.
The bar hanger brackets are shipped flat. Bend the tabs on the brackets as
shown to allow the use of accessory mounting channels or bar hangers.
Mount the frame in the ceiling so that the weight of the assembly is safely
supported by the mounting channel or bar hangers.
2.
Remove the top of the housing and adjust the frame so the bottom surface is
flush with the backside of the ceiling material and in alignment with adjacent
fixtures. The rivets for the 8" x 8" polycarbonate cut-through panel may be
used as centerlines (as shown) for aligning the frame. Secure the mounting
brackets by tightening wing nuts on either side of the frame inside the P8556
housing.
3.
IMPORTANT! When the ceiling material is added (covering the P8556)
make sure the P8556 is flush with the backside of the ceiling material and
solidly mounted. Mark the fixture installation location accurately so the hole
cut-through location will be accurate!
4.
There are (4) 3/8" MC flexible conduit entry points located on the rear cover
plate of the P8556 to allow the UNENERGIZED line voltage flexible conduit
to be inserted into the housing until they are used when the P8152/P8153
fixture is wired and installed. There are (4) conduit gaskets included with the
P8556 housing to be used if needed to seal the conduit opening further after
the flexible conduit is installed. There is also a tether cable mounted inside
the housing to be attached to the P8152/P8153 fixture in the case of seismic
conditions at the install location. This tether, if needed, should be attached to
the screw on the light engine (see Detail A) after the wiring is complete and
the J-tube is inserted in the ceiling, but before the fixture is installed.
5.
Install the P8152/P8153 fixture per the instruction sheet provided with the
fixture. When the hole is cut in the ceiling with a 2 7/8" hole saw, it will cut
through the polycarbonate cut-through panel at the same time providing
accurate alignment in both the ceiling material and the P8556.
6.
WARNING! DO NOT pinch wires between the J-tube cover and J-tube
endplates. Consult a Qualified Electrician for all other options that
require other wiring configurations.
CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIXTURE.
SAFETY AND PROPER OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING.
701 Millennium Blvd, Greenville, SC 29607
With representative offices in principal cities throughout North America.
Copyright 2015, 07-07-15 revision, All Rights Reserved
INSTALLATION INSTRUCTIONS
8" x 8"
Polycarbonate
Panel
Cut-Through
Area
Extra
Conduit
Gaskets
3/8" Flexible
Conduit
Entry Points
Seismic
Tether
P8152/P8153
Fixture Screw
DETAIL A
P8556 WITH P8152/P8153 INSTALLED
P8556 Series
.
SPEC. NO
93063441