DUPLEX TURBO
MAINTENANCE
7.3
Replacing the scrapers
Keep the two recovery tank scrapers (11) clean at all times.
Replace them approximately every 150 work hours or when they are visibly worn.
To replace the scrapers 11, proceed as follows:
1)
Remove the cover 4.
2)
Remove the recovery tank 5.
3)
Unscrew the screws 12 and remove the worn scrapers 11.
4)
Replace the scrapers 4 and tighten the screws.
7.4
Conveyors
The conveyors 13 have an unlimited lifespan.
CAUTION
Do not use the appliance to collect sharp object that could cut
through the rubber.
In order to always keep the belts 13 in good working order, we recommend cleaning them
periodically and lubricating them with a silicone spray.
4
13
12
13
122
11
11
12
5
F.53
Rev.
1.0