BGS technic 6932 Guia De Inicio Rapido página 4

Extractor del cojinete del alojamiento del diferencia
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USE
PULLER MOUNTING
1 Retaining bolts
2 Spindle
3 Puller bridge with inserted retaining bolts
4 Clamping bridge
4s Clamping screws
5 Puller feet
6 Stepped disc with choosen diameter
A Differential cage
B Bearing
1. Connect the clamping bridge (4) with the puller feet (5). Use the 2 screws (4s) for this.
Determine the distance between the puller feet (5) and connect them to the puller bridge (3) with
the 2 retaining bolts (1).
When mounting, make sure that the spindle (2) has to be guided through the clamping bridge (4).
2. Choose the stepped disc (6-7-8-9) with a suitable diameter and place it on the bearing stub of the
differential cage.
3. Position the puller feet under the bearing and the spindle tip on the stepped disc.
4. Tighten the puller feet with the two screws (4s) of the clamping bridge (4).
5. Turn the spindle clockwise to slightly pre-tension the puller.
6. Check that the puller is in the correct position.
7. Turn spindle further clockwise and remove bearing.
NOTIZEN
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed