Helpful Tips - RealFlame 9670LP Manual Del Usuario

Hogar de la tabla cuadrada mezzo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

If the burner will not light or stay lit,
please perform the following checks.
It is possible that the Excess Flow Safety Device has been tripped.
Turn the control knob to off and close the LP Gas tank valve. Disconnect the
regulator. Turn the Control Knob to "HIGH". Wait a minimum of 5 minutes.
Turn burner control knob back to "OFF". Reconnect the regulator and perform
a leak check at tank connection. Turn the LP Gas tank valve on slowly, wait 30
seconds and then light the outdoor fire table.
To ensure proper ignition make sure the igniter pin is properly positioned
and connected.
The Igniter Pin must be 3 mm (1/8") away from the burn tube. (Below Left)
The ignition wires must be fully inserted into the ignitor box. The ignitor box
is located next to the control valve under the unit.
Thermocouple
Make sure that the pilot housing is unobstructed.
Clear any debris on top of the pilot housing and make sure there is no debris
between the igniter pin, thermocouple and the burner tube.
CORRECT
All manuals and user guides at all-guides.com

Helpful Tips

3mm
Igniter Pin
Pilot Housing
If wires are too
close, or
tangled, they
could short.
Make sure they
are spaced
apart from
each other.
Burner
Tube
Do not block
opening
Make sure
the wires are
fully inserted
into the
ignitor box.
INCORRECT