1
GENERAL SAFETY
1.1
ELECTRICAL SAFETY
-
Disconnect any units plugged into the mains before doing any assembly or maintenance
jobs on the junction boxes.
-
Do not touch the water or get into the water while the units are connected to the power
supply.
-
Connect the unit to an equipotential bonding connection. Use the slots on the box's
mounting brackets.
Use an H07RN-F type waterproof cable.
-
1.2
SAFETY IN USE AND CONTACT WITH WATER
-
The water in the fountain where the unit is to be fitted must meet the following conditions:
Characteristics of the
water
Temperature
pH
Free residual chlorine
Total alkalinity (TAC)
Calcium hardness (CH)
Salt level
Total dissolved solids
(TDS)
In the event of cold spells with temperatures below 4 ºC, avoid contact with frozen water
-
to prevent the unit from breaking due to the formation of ice.
-
Do not tamper with the factory-fitted waterproof seals. Otherwise, the unit could lose its
warranty.
Minimum value
4 °C
6.9
0.5 ppm
80 ppm
200 ppm
-
-
Maximum value
35 °C
7.8
2.0 ppm
120 ppm
1,000 ppm
2 g/l
2,000 ppm
Fountain units