Introduction
This manual provides operating instructions for the PV 212
hydraulic hand-pump.
Safety
The manufacturer has designed this equipment to be safe
when operated using the procedures detailed in this
manual. The user must not use this equipment for any other
purpose than that stated.
This manual contains safety and operating instructions that
must be followed to make sure of safe operation and to
keep the equipment in a safe condition. The safety
instructions are either warnings or cautions issued to
protect the user and the equipment from injury or damage.
Use suitably qualified technicians
practice for all procedures in this manual.
Pressure
Do not apply pressure greater than the maximum safe
working pressure stated in the specification.
Toxic Materials
There are no known toxic materials used in construction of
this equipment.
Maintenance
The equipment must be maintained using the procedures
in this publication. Further manufacturer's procedures
should be done by an authorized service agents or the
manufacturer's service departments.
Technical Advice
For technical advice contact the manufacturer or
subsidiary.
Symbols
The following symbols mark this equipment:
Symbol Description
This symbol, on the equipment, indicates a warning
and that the user should refer to the user manual.
Ce symbole, sur l'appareil, est un avertissement qui
indique que l'utilisateur doit consulter le manuel
d'utilisation.
Do not dispose of this product as household waste.
Use an approved organization that collects and/or
recycles waste electrical and electronic equipment.
For more information, contact one of these:
- Our customer service department: Druck.com
- Your local government office.
Abbreviations
The following abbreviations are used in this publication.
Note: Abbreviations are the same in the singular and
plural.
Abbreviati
Description
on
°C
degrees Celsius
BSP
British Standard Pipe thread
COSHH
Control of Substances Hazardous to Health
regulations
°F
degrees Fahrenheit
lb
pounds
*
A qualified technician must have the necessary technical
knowledge, documentation, special test equipment and
tools to carry out the required work on this equipment.
and good engineering
*
Abbreviati
Description
on
kg
kilogram
mm
millimetre
MSDS
Material Safety Data Sheet
NPT
National Pipe Thread
psi
pounds per square inch
PTFE
polytetrafluoroethylene
1. Introduction
The PV 212 is a portable source of hydraulic pressure.
Each pump includes a reservoir, and a volume control for
fine adjustment. To prevent damage to sensitive
instruments, there are five pressure relief valves available
for different pressure ranges.
2. Operation
WARNING
Before applying pressure, make
sure all connections are correct and
equipment is internally clean and free from
damage.
Make sure that all equipment is to the correct
pressure rating.
Do not exceed the maximum operating
pressure stated in the specification.
Observe the relevant health and safety
precautions.
CAUTION
If PTFE tape is used to seal NPT
threads, ensure that only a sufficient amount
is used to achieve pressure seal. If excess
tape is used, particles can become loose
during the connector mating process and
enter the pump, potentially leading to loss of
pump performance or pressure leaks.
Note: Wherever possible, use o-ring seals in the BSP
connection ports this is the recommended method of
sealing.
Key to Figure A1
1. Pressure release valve.
2. Fine adjust vernier.
3. Prime/High pressure selector.
4. Scissor handles.
5. Reservoir.
6. Fluid inlet tube.
7. Reservoir fill plug.
8. Output port.
9. Output port.
10. Rear port for an optional pressure relief valve. Do not
use for other functions.
11. Recommended fluid level.
2.1 Connecting the Pump
BSP ports can be fitted with any suitable length ¼ BSP
male connector, sealing either with an o-ring at the bottom
of the port or a bonded seal at the top. Adaptors are
supplied to convert the BSP ports to ¼ NPT. Fit a suitable
blanking plug to an unused port.
2.2 Pressure Release Valve (Figure A1)
Use this (1) to reduce or release the pressure in the
system. The amount of turn sets the rate to release the
Copyright 2005 Baker Hughes Company.