Settings
Enter SETUP mode and adjusting settings.
With the shower off (but with the Base Unit still connected to
mains electricity supply), press Pause and Override (+)
buttons simultaneously for approximately 5 seconds.
=>The word SETUP will be displayed.
Press the Override (+) button to scroll through the following
options:
The options will return to the top of the list after the last one
is reached.
Safety information
By changing pre-settings of START T, OVERRIDE or
MAXTEMP to values more than 43 °C danger of
scalding!
Display
Function
START T
The Start button
in °C (20 °C to MAX-TEMP
in 0.5 degree steps)
OVRRIDE
The temperature at which the
Override (+) must be pressed
before further increasing the
temperature (20 °C to
MAXTEMP in 0.5 degree steps)
MAXTEMP
The maximum temperature that
the shower allows (30 °C
to 65 °C in 0.5 degree steps)
DEGREE
To switch between Centigrade
and Fahrenheit
DECIMAL
To switch between showing the
decimal or not
SYNCHRO
To synchronise water
temperature - only for installers
(34 °C to 42 °C in 0.5 degree
steps)
ONFLOW
To change the Start button
flow rate (1 to 12)
FALLBAK
To change the flow rate after
starting the water flow from the
Remote Controller (1 to 12)
MAXFLOW
The maximum flow setting
(0 to 100)
MINFLOW
The minimum flow setting
(0 to 99)
7
Default
38 °C
temperature
38 °C
43 °C
Centigrade
Decimal
38 °C
9
1
100
50
Display
Function
ONDELAY
A shower start delay for user
convenience when using Main
Controller only (0 to 3
in 0.5 second steps)
BACKLIT
The time the display backlight
remains illuminated (0 to 30
in 1 second steps)
I TIME
The automatic switch off time
when using the Main Controller
(0 to 30 in 1 minute steps)
P TIME
The automatic switch off time
when using the Pause function
(0 to 30 in 1 minute steps)
R TIME
The automatic switch off time
when starting from the Remote
Controller (0 to 30 in 1 minute
steps)
Change the above settings by turning the Temperature
Knob then press the Pause Button to confirm. Finally, exit
the SETUP menu by selecting EXIT (otherwise the change
will not be saved).
Display
Function
REGISTR
To register new controllers, siehe Seite 8
RESET
To reset to factory default settings
VERSION
To find out which software version is
installed
SERVICE
To enter a service mode – only for service
engineers
EXIT
To exit the SETUP menu
Press Pause to activate the above.
Note: The Main Controller will automatically exit the SETUP
menu if no adjustments are carried out over a 5 minute period.
No setting changes will be saved in this case.
Default
0.5 secs
10 secs
30 mins
5 mins
5 mins