Ocultar thumbs Ver también para Lumnia Standard:

Publicidad

All manuals and user guides at all-guides.com
Lumnia Standard - Instruction Manual
+
Includes Lumnia
Encapsulation Module
This manual is based on the latest information and is provided subject to alteration.
We reserve the right to change the construction and/or configuration of the product
and versions at any time without obligation.
All rights reserved. No part of this document may be reproduced, stored in a database or any other retrieval
system, or published, in any form or way, electronically, mechanically, digitally per photo print or microfilm or
any other way without written permission from the author.

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Rentokil Lumnia Standard

  • Página 1 All manuals and user guides at all-guides.com Lumnia Standard - Instruction Manual Includes Lumnia Encapsulation Module This manual is based on the latest information and is provided subject to alteration. We reserve the right to change the construction and/or configuration of the product and versions at any time without obligation.
  • Página 2 All manuals and user guides at all-guides.com 1. Safety Warning The lamps in this unit produce ultraviolet (UV) light, which can cause skin or eye damage if viewed directly for a long period. Only fit the correct type of UV lamps in the unit. The unit shall be installed and serviced by individuals with appropriate qualifications and/ or experience in accordance with national...
  • Página 3 All manuals and user guides at all-guides.com WARNUNG ADVERTENCIA Die Lampen in diesem Gerät erzeugen Las lámparas de esta unidad producen ultraviolettes (UV)-Licht, das Haut- oder luz ultravioleta (UV), que puede provocar Augenschäden verursachen kann, falls man daños en la piel o en los ojos si se mira für längere Zeit direkt hineinblickt.
  • Página 4 All manuals and user guides at all-guides.com AVERTISSEMENT WAARSCHUWING Les lampes de cet appareil produisent une De lampen in dit toestel produceren lumière ultraviolette (UV) susceptible de ultraviolet (UV) licht, dat huid- of oogschade causer des dommages à la peau ou aux kan veroorzaken indien men gedurende yeux en cas d’exposition prolongée.
  • Página 5 All manuals and user guides at all-guides.com UYARI ADVARSEL Üründeki lambalar ultraviyole (UV) Lampene i denne enheten produserer ışık üretmekte olup, bu türde ışık ultrafiolett (UV-lys) doğrudan uzun süre bakıldığında cilt forårsake skader på hud eller øyne hvis veya gözde hasara yol açabilir. Ürüne du ser på...
  • Página 6 All manuals and user guides at all-guides.com AVVERTENZA AVISO Le lampade in questa unità producono As lâmpadas desta unidade produzem luzes ultravioletas (UV) que podem luce ultravioletta (UV), che può causare danni alla pelle o agli occhi se vi si provocar danos oculares ou cutâneos è...
  • Página 7 All manuals and user guides at all-guides.com 2. Introduction The Lumnia Standard unit uses two ultra-violet LED driven lamps that attract flying insects that are then captured on a replaceable glue board or encapsulation module. The modular design of this unit allows for both. The standard product comes as a glue board control device which can be upgraded to a monitoring device by adding the Lumnia + encapsulation module.
  • Página 8: Connecting The Power Source

    4. Connecting the Power Source NOTE: Cable Assembly not supplied in box. Ordered direct from Rentokil Initial to meet specifi c country requirements. WARNING: You must NOT connect the unit into a lighting circuit. You must connect the power cable to a standard power socket.
  • Página 9: Positioning The Unit

    All manuals and user guides at all-guides.com 5. Positioning the Unit Position the unit on a suitable wall at a minimum height of 1.8 metres to the bottom of the unit. Figure 1 illustrates the suggested mounting height and illustrates what happens during service mode.
  • Página 10 All manuals and user guides at all-guides.com For safety reasons, the unit contains a micro switches that disables the UV lamps if you open the Front Louvre or if the products service mode (Slide) is activated. See section 7 and 8. Figure 2 indicates the size and space considerations for louvre cover opening sweeps at 90°.
  • Página 11: Installation Preparation

    All manuals and user guides at all-guides.com 7. Installation Preparation 1.8M Ø6mm...
  • Página 12 All manuals and user guides at all-guides.com Opening the Louvres Mounting Lumnia NOTE: Remove lamps before screwing See Section 12 for more details on lamp removal SECURE WITH ALL 4X SCREWS...
  • Página 13 All manuals and user guides at all-guides.com 8. Activating the Slide Mechanism 9. Preparing the Glue Board Fold Flex Remove Liner...
  • Página 14 All manuals and user guides at all-guides.com 10. Installing the Glue Board 11. Removing the Glue Board...
  • Página 15 All manuals and user guides at all-guides.com 12. Removing and Replacing the UV - LED Lamps Removing UV - LED Lamps Do not touch LED when servicing, maintaining or cleaning the lamps. NOTE: Ensure the lamp is pushed fi rmly back into the left hand fi tting...
  • Página 16 All manuals and user guides at all-guides.com 13. User Interface Settings Functions for use with Lumnia ONLY: See Section 17 for Lumnia User Interface Mode Button I = Low II = Med III = High A A A C C C A = Adaptive Low* B = Adaptive Med* C = Adaptive High*...
  • Página 17 All manuals and user guides at all-guides.com 14. Lumnia Encapsulation Module Your Lumnia Standard can be turned from a monitoring device to a control device in areas where fl y infestations may occur. A motorised Encapsulation Module can be purchased to use with your Lumnia.
  • Página 18 All manuals and user guides at all-guides.com 16. Loading Lumnia Encapsulation...
  • Página 19 All manuals and user guides at all-guides.com 17. Lumnia Encapsulation Interface Settings See Section 14 for fi tting the Lumnia+ Module The interface is activated when the Module is inserted Lumnia User Interface Glue Roll Manual Override Glue Roll Service Day Setting 30 day setting rolls on a clean glue surface every 24 hours Mode Button...
  • Página 20 All manuals and user guides at all-guides.com 18. Glue Roll Manual Override GREEN: OPERATIONAL RED: FAULT NOTE: Counter for Lumnia Encapsulation Module resets when removed from Lumnia. Important that module is removed for a new Glue Roll...
  • Página 21 All manuals and user guides at all-guides.com 19. Servicing: Replacing the Glue Roll Part Part Part Part Part Reuse parts A - E above to create the new Roll Assemblies below New Roll With emboss Without emboss Part Part Part Part Part...
  • Página 22: Accessories And Spares

    Rentokil can accept no liability whatsoever for any loss or damage arising from the product being...
  • Página 23 • Boxed Unit 6.7 kg (boxed) • Unit including Lamps 5.14 kg & Glueboard • Lumnia+ Encapsulation 1.35 kg (unit) Module Lumnia+ Encapsulation Module 24V DC Refer to Lumnia Standard Manual for full installation instructions, scan the QR code or visit: www.rentokil.com/manuals...
  • Página 24 Rentokil reserve the right to alter the specification or design without prior notice. Rentokil cannot accept any liability for any loss or damage arising from the use of any information contained within this manual, or from any incorrect use of the product described herein.

Tabla de contenido