Operatation Guide
Notes :
A. When turning the knob clockwise slowly, increment by 1 min
B. When turning the knob clockwise faster than A., increment by 10 min
C. When turning the knob clockwise faster than B., increment by 1H
D. When turning the knob clockwise the fastest possible: increment by 4H
E. Same logic when turning the knob counterlockwise (decrease the value)
F. If there is no operation for 20 sec, the display will return to the main screen
G. The service function is used for alerting the user when it is time to change a filter
or to serivce the equipment after the accumulated run time is reached.
Rotate
Escape
Rotate
Escape
Rotate
Main Screen
Escape
Rotate
See notes G
Escape/Rotate
The icon
will flash on main screen when filter or service timer done,
push and hold ESC button 4 seconds to reset the filter or service time.
English 4
Rotate to change CLOCK (H+MIN), see notes A to E
Enter
Enter
Save and return
to Main Screen
Escape
Rotate to change START TIME
Rotate to change STOP TIME
Enter
Enter
Escape
Escape
Enter
Timer 2, Timer 3, Timer 4 same setup method as Timer 1
Rotate to change filter or service number
Enter
Enter
Save and return
Escape
to Main Screen
Escape
Enter
Save and return
to Main Screen
Specifications
Operation: Four Timers available
(4 x ON/OFF cycles/day)
Input Voltage: 100 to 250Vac. 50/60Hz
Pump Ratings: 0.5HP ~ 3HP (6~20FLA)
•
1/2HP ~1.5HP at 110Vac, 50/60Hz
•
1/5HP ~ 3HP at 230Vac, 50/60Hz
Power Relay: 2 pole, 25A rated
Operation Temperature: -10℃ to 50℃
?
For information regarding operation,
available options, or servicing
questions, please call an
SJE Rhombus customer service
technician:
1-800-Rhombus (1-800-746-6287)
Monday-Friday, 7:00 AM to 6:00 PM Central Time
Manufactured by: SJE Rhombus
©SJE Rhombus
PN1067582A
Rev 12/20
TimeZone
Digital Timer Control Panel
Installation Instructions and
Operation Manual
Part Number / Circuit Breaker:
1067561S / 2 pole 16A for pumps rated for 0-12A
1067560S / 2 pole 25A for pumps rated for 9-20A
Clock: Real Time clock with Super Capacitor power
Accuracy: Turn ON/OFF time set accuracy (1 min)
Enclosure: Thermoplastic, TYPE 4X/IP65
This control panel must be installed and serviced by a licensed electrician in
accordance with the National Electric Code NFPA-70, state and local electrical codes.
UL Type 4X enclosures are for indoor or outdoor use.
Warranty void if panel is modified.
SJE Rhombus offers a five-year limited warranty.
For complete terms and conditions, please visit www.sjerhombus.com.
Products returned must be cleaned, sanitized, or decontaminated as necessary
prior to shipment to ensure that employees will not be exposed to health hazards
in handling said material. All applicable laws and regulations shall apply.
Toll free: 1-888-DIAL SJE
22650 County Highway 6
(1-888-342-5753)
PO BOX 1708
Phone:
218-847-1317
Detroit Lakes, MN 56502 USA
Fax:
218-847-4617
™
backup (5 days)
(20.3 x 15.2 x 10.2 cm)
Email:
customer.service@sjerhombus.com
Website: www.sjerhombus.com
English 1