• The yellow-green wire in the air conditioner is the grounding wire, which cannot
be used for any other purposes.
• The grounding resistance should comply with national electric safety
regulations.
• The appliance must be positioned so that the plug is accessible.
• An all-pole disconnection switch with a contact separation of at least 3mm for
all poles should be connected in fixed wiring.
Installation of indoor unit
Step 1: choosing the installation location
Recommend the installation location to the client and then confirm it with the client.
Step 2: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust its position horizontally with
the level and then mark the screw fixing holes on the wall.
2. Drill the screw fixing holes in the wall with impact drill (the specification of drill
head should be the same as the plastic expansion anchors) and then insert the
plastic expansion anchors in the holes.
3. Fix the wall-mounting frame to the wall self with tapping screws (ST4.2X25TA)
and then check if the frame is firmly installed by pulling on the frame. If a plastic
expansion anchor is loose, please drill another fixing hole nearby.
Step 3: open pipe hole
1. Choose the position of the pipe hole according to the direction of the outlet pipe.
The position of the pipe hole should be a little lower than the wall-mounted frame,
as shown below.
QB:
Wall
Mark in the middle of it
Left
�55 mm
Level
Rear pipe hole
Rear pipe hole
2. Bore a pipe hole with a diameter of � 55 in the selected outlet pipe position. In
order to drain smoothly, slant the pipe hole in the wall slightly downward towards
the outdoor side with the gradient of 5-10°.
Indoor
5 - 10°
Note:
• Pay attention to dust prevention and take appropriate safety measures when
opening the hole.
• The plastic expansion anchors are not provided and should be bought locally.
12
G306MA_AF1_AC18_indoor_170216.indd 12-13
QD:
Wall
Wall
Mark in the middle of it
Space
Space
to the
to the
wall
wall
above
above
150 mm
150 mm
Left
Right
Right
�55 mm
�55 mm
�55 mm
Level
Rear pipe hole
Rear pipe hole
Outdoor
� 55
Step 4: outlet pipe
1. The pipe can exit the unit to the right, rear right, left or rear left.
2. If the left or right exit for the pipe is chosen, please cut out the corresponding
opening in the bottom of the housing.
Wall
Step 5: connect the pipe of indoor unit
1. Align the pipe joint with the corresponding bellmouth.
2. Pretighten the union nut by hand.
3. Adjust the torque force by referring to the following table. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten the
union nut with the torque wrench.
pipe joint
Split Air Conditioner | Aire acondicionado Split | Ar condicionado Split
left
rear right
right
left
right
cut out the
opening
union nut
pipe
torque wrench
indoor pipe
EN
rear left
open-end
wrench
union nut
pipe