PROBLEM
The light does
not work; the
motor does
not work
Oil leakage
The body of
the appliance
shakes
Insufficient
suction
The machine
inclines
10 6
AF Manual Instruções Manual Campanula Parede BCHTS2340 A5.indd 21
CAUSE
Beside what is listed above, please check the following
The light is damaged
The power cord is loose
The one-way valve and
the air ventilation entrance
are not sealed tightly.
Leakage from the
connection between the
U-shaped section and the
cover
The leaf is damaged and
causes shaking
The motor is not hanged
tightly
The body is not hanged
tightly
The distance between the
body and the gas top is
too long
Too much ventilation from
open doors or windows
The fixing screw is not
tight enough
The hanging screw is not
tight enough
Cooker Hood | Campana de cocina | Exaustor
SOLUTION
Replace the lights
Connect the wires as per
the electric diagram
Take down the one-way
valve and seal it with glue
Take the U-shaped section
down and seal it with soap
or paint
Replace the leaf
Lock the motor tightly
Fix the body tightly
Readjust the distance
Choose a new place and
reassemble the appliance
Tighten the hanging screw
and make it level
Tighten the hanging screw
and make it level
EN
03/07/17 11:17