After 10 minutes of continual skin exposure, a 30-minute break is to be taken. UV lamp
should not be used more than 200 times per year.
•
The minimum distance between the user and the UV LED is 20 mm.
•
The product may not be used when the timer is damaged or has been removed.
•
As with the sun, the UV radiation from UV lamps can lead to damage to the skin or eyes.
This possible damage is influenced by the quality and quantity of use and the sensitivity of
the user's skin or eyes.
•
If the eyes are not protected, frequent use of the lamp can cause damage to the retina
and a cataract may develop. In several cases this has resulted in the recurrence of a
cataract that had been previously operated on.
•
People who react sensitively to UV light, certain medications or cosmetic products should
be particularly protected when using the appliance or abstain from working with this
appliance altogether.
•
Remove all cosmetic products from the skin, such as moisturizer and sunscreen, before
use.
•
You must consult a physician before use if you are taking medication that makes you
more sensitive to UV radiation (e.g., St John´s Wort).
•
There must be a 48-hour long pause between 2 treatment sessions.
•
Please consult a dermatologist immediately if skin irregularities (minor lumps), skin pain
or pigmentation changes such as moles arise.
Operating the unit
1.
Plug the power adapter (G) into the socket and the power adapter plug (H), on the rear
side of the device, into the power adaptor socket intended for this purpose (F).
2.
There are 2 options for switching on the Promed UVL-54 All-In:
Infra-red sensors; Here, the device is started when the hand is placed in the device and
the timer counts upwards. Once the desired curing time has been reached and the hand
is removed, the device switches off again.
Time switch; After inserting the hand, push one of the 4 time switches according to the
desired duration of use (10 s (E), 30 s (D), 60 s (C) and 99 s (B)). The device starts and the
elapsed time is displayed in the timer display (A). The device can be stopped at any time
by pushing the button again.
3.
Painless mode: To activate painless mode, start the device with the 99s/painless mode
button (B). This starts the device with a low LED output and increases this in 3 steps to
the maximum value.
4.
Low power mode: If you have started the device using the sensors or the time switch 10
s (E), 30 s (D) or 60 s (C), you can reduce the output for this application at any time from
54 W to 48 W. To do this, hold the 99s/low power mode button (B) for approx. 2 seconds