The following instructions contain important safety information
GB
Prior to installation please read carefully these instructions (especially the "Safety Notices").
Keep these instructions to consult them after installation if necessary.
NOTES ON THE radio transmitter
UHF band transmitter with PPL controlled carrier frequency. This type of transmitter is used for controlling devices for domestic use, automatic
openings, etc.
This appliance transmits a rolling-code type .signal to guarantee maximum secrecy.
The transmitter code can be stored in the receiver directly via the latter or via radio from the transmitter. With the second possibility you can
add new transmitters to an existing system without having to touch the receiver. This can be done directly by the end user (the installer's help
is not required).
The code is stored in the receiver's EEPROM memory that retains it even if power is cut temporarily.
The transmitters are coded directly by the manufacturer with a different code for each transmitter.
The operator is in no way protected against interference from other telecommunication equipment or systems (e.g. authorised radio systems
working on the same frequency range). If you are having problems with its range of action, fix the manual transmitter up high. Change the
battery if necessary
SAFETY NOTICES
Keep this manual transmitter out of the reach of children and animals.
Do not use the manual transmitter in places or where systems are sensitive to radio emissions (e.g. airports, hospitals).
Do not keep or use the manual transmitter in places that are damp, where there is steam, high air humidity, dust or where it is exposed to
the direct rays of the sun or similar environmental conditions.
Do not let the manual transmitter drop: it could be damaged or its range of action reduced
CHANGING THE BATTERY
Keep the batteries out of the reach of children. Call a doctor immediately if a battery is swallowed.
Explosion hazard if the battery is substituted incorrectly.
Replace the battery with a CR2430 type battery only.
Always wrap the battery up, both when it is being stored and when it is being disposed of. The battery should not come into contact
with other metal objects as it could cause the battery to run down, catch fire or be damaged.
Dispose of damaged or finished batteries immediately in compliance with the law. To this end, contact the authorities for
safeguarding the environment or the centre for disposing of waste materials in your area. Do not throw the battery away with
household rubbish
Remove the screw on the back.
Slide each other the two cases and open.
Take the old batteries out and put the new ones in the same way. Pay attention to correct polarity (+/-)!
Close the transmitter with the screw.
Rev 08/02/2019
P3
HOW TO STORE A TRANSMITTER VIA RADIO
WITHOUT ACCESSING THE RECEIVER BY MEANS
OF A PREVIOUSLY STORED TRANSMITTER
Press the internal key P3 of a previously stored transmitter, the enabled receiver
1 2 3 4 5 6
emits a continuous sound for 5 seconds.
Transmit a channel present in the memory of the receiver, in which the new code is
to be memorized, within 5 seconds and the buzzer will interrupt the sound for 1 sec,
and then carry on for another 5 seconds.
SEL
Transmit the new channel to store within 5 seconds, confirmed by intermittent
buzzing.
SEL button: multi-transmitter function
Each LED position represents a transmitter, in total 6 positions. Press the SEL buttons from
1 to 6 times in order to select the desired position. The selection remains memorized until
OPEN
the next variation, even with transmitter off; it is sufficient to press a channel push
button to reactivate the last selection
Channels limitation function
STOP
In order to activate the channels limitation function press the button SEL as many times as
the maximum number of groups you want to use and keep it pressed the last time for 5
seconds. The channels limitation is signalled by the flashing of the LEDs relative to the
CLOSE
selected groups:
LED1 up to Group 1,
LED2 up to Group 2,
LED3 up to Group 3,
LED4 up to Group 4,
LED5 up to Group 5.
In order to deactivated the channels limitation function press SEL button for 5 seconds.
All the LEDs will flash.
GUARANTEE
Ultraflex Control Systems S.r.l. products are guaranteed, for a period of two years from the manufacture date, against defects in material and
workmanship.
Alleged defective products returned, freight prepaid, within the above said term, will be repaired or replaced free of charge, at our option, if
found effectively below our quality standards.
This guarantee does not cover other claims for direct or indirect
damages.
In particular, we decline liability and exclude guarantee (except for what stated above) if improper installation or misuse should result in a
failure of our products.
The batteries are not covered by the guarantee.
CORRECT DISPOSAL OF THIS PRODUCT
The correct disposal of your old appliance will help prevent potential negative consequences for the environment.
Under art. 14 of the 2012/19/EU DIRECTIVE OF THE EUROPEAN PARLIAMENT AND COUNCIL of 4 July 2012 on waste electrical and electronic
equipment (WEEE). The crossed bin symbol on the equipment, or its packaging, indicates that the product must be collected separately from
other waste at the end of its useful life and not with mixed urban waste. Please contact your municipality, or local authority, for all information
regarding the waste sorting systems available in the area. The retailer is obliged to collect the old equipment free-of-charge when the customer
buys a new equivalent equipment. This is to encourage correct recycling/disposal. Appropriate waste sorting for the subsequent
recycling,reatment and disposal in an environmentally sound way of the disused equipment avoids negative effects on the environment or
human health and favours the re-use or recycling of the equipment's materials.
DECLARATION OF CONFORMITY TO THE EU DIRECTIVES
Hereby ULTRAFLEX CONTROL SYSTEMS s.r.l. declares that the products comply with the essential requirements and other relevant provisions,
established by the Directive 2014/53/UE.
The declaration of conformity can be consulted on the web site: http://www.ultraflexgroup.it/ucs
Dis. 32141/b