My modules will not respond to my controller.
Make sure that the House Code on all Modules and Controllers are set to the same House
Code (A .. P).
My modules will not react to my remote / sensor.
When you use a remote or sensor, you should have at least one TM13 Transceiver or
Marmitek Security Console installed in your house. These components will translate the radio
signals to the Marmitek X-10 signal on the power line. Only one Transceiver should be
installed for all remotes and sensors set to the same House Code.
Am I able to increase the range of my remotes by using more Transceivers?
Yes, you can use more than one TM13 Transceiver in your home when the range of your
remotes is not sufficient. The TM13 is using so called collision detection to prevent signals to
be disturbed when more than one TM13 is transmitting. TM13's will wait for a quite power
line before transmitting their data. To prevent your Marmitek X-10 System to become slow or
to prevent dimming from becoming less smooth, make sure that the TM13 units are placed as
far away from each other as possible.
USER INSTRUCTIONS AD10 DIN RAIL SWITCH
SWITCH OFF APPROPRIATE MAINS FUSE AND MASTER SWITCH!
(INSTALLATION BY A CERTIFIED INSTALLER)
1. Mount the AD10 using the schematics below.
2. Set the rotary code switches on the front side to the desired address.
Technical data
Supply voltage:
Supply current :
Switching power:
Signal sensitivity:
Input impedance:
Connection:
Ambient temperature:
Dimensions:
AD10
TM
Description of the selector switch:
Position 0: Always Off
Position 1: Always On
Position Auto: Control with Marmitek X-10 Controllers and
attached switches possible
Terminal 1 of the switch is designed for toggle switches: the
relay picks up when phase is present and releases when there is
no voltage at the terminal.
Terminal 2 of the switch is designed for pulse contacts. Each
time phase is applied, the relay switches (i.e. from OFF to ON or
vice versa).
230VAC / 50 Hz
< 20 mA capacitive
3600W/230V for resistive (ohm) load
700W/230V for inductive/capacitive load
2000W/230V for light bulbs and halogen lighting
15 mVpp min 50 mVpp max at 120 kHz
> 180 Ohm (L - N) at 120 kHz
Connection: Connecting clamps for phase, neutral, switched phase,
switch and momentary switch.
- 10° C to + 50° C (operation) - 20° C to + 70° C (storage)
35x80x70mm
5