Installation Instructions/Instrucciones de Instalación
INLET
OUTLET
7. Attach the sensor cable (1)
and transformer cable (2).
8. Plug the transformer (3) into
electric outlet so normal operation
can begin.
Place hands in the sensor field
PROBLEM
No water running
Water does not turn off
Very low water flow
Too high water flow
Short battery life
The sensor light
does not turn on
5. Mount the control box in an accessible location (1).
6. Install supply lines to the inlet and the outlet (2).
SENSOR
CABLE
How to Use
Water runs for 60 seconds and
then shuts down
Troubleshooting
CAUSE
The batteries are exhaused
Watter supply cut off
Dirt in the filter
Water pressure too low
Dirt in the sensor window
Water supply is obstructed
The filter is too dirty
Water pressure is too high
Incorrect batteries
The batteries are exhaused
The circuit board is wet
or signal line is wet
Poor connection to batteries
The light is broken
5
TRANSFORMER
CONNECTOR
Remove hands from sensing field for 3 seconds
to repeat the cycle
SOLUTION
Replace the batteries
Check water supply lines
Clean the filter
Increase the water pressure
Clean the sensor
Adjust water supply
Clean the filter
Adjust water pressure down
Use 4 AA Alkaline batteries
Replace the batteries
Dry out all supply lines
Check/plug in all connections
Change the light or circuit board
LACAVA