Pág. 14
VR360 Minicablecam Control
Using the remote:
1. To scroll through the menu, turn the control knob.
2. Short press on the control wheel: select / enter / activate / execute.
3. Long press on the control wheel: perform the exit / return / end / power off action.
Manual mode: Allows you to control the movement in real time.
• Turning the knob will cause the speed to increase or decrease in one of the two directions of rota-
tion.
• One press of the knob will cause direct passage to speed 0.
NOTE: A loss of connection between the control and the device will also cause a safety braking.
Auto mode: Allows you to program a movement and play it whenever you want with different accele-
ration and speed parameters.
Single-section automatic movement
• Press the knob by positioning the cursor on the scroll line.
• By moving the control knob it is possible to move the axis and by clicking to establish the initial
position of the movement.
• A quick double press will go back in the recording sequence, allowing you to change previously set
points.
• Once all the necessary points have been established, keeping the knob pressed will finish the pro-
gramming and the device will take the axis to the initial point that has been established.
• After the points have been recorded, the speed (SPEED1) and acceleration (RAMP) parameters
can be set.
selection of speeds due to the fact that the available distance is not enough to reach the highest
speeds.
Accelerations will always have a symmetrical profile, that is, the same distance will be reserved for
accelerating as for braking.
section successively forward and backward. One press of the knob will stop the movement and re-
turn the appliance to the initial position.
SPEED1: Defines the speed on a scale from 1 to 40. It is possible that the system limits the
RAMP: Defines the percentage of travel that will be used to accelerate and decelerate.
REPEAT: We can choose between a repetitive movement that reproduces the programmed
GO: A press with the cursor on GO launches the movement start sequence.
English