i-tec MySafe USB-C / USB 3.0 2x M.2 SSD RAID External Case
SPECIFICATION
• Extern USB-C case for 2x M.2 B-Key SATA Based SSD disks
• Transmission interface: 1x USB-C, Gen 2
• Compatible with M.2 B-Key SATA Based SSD disks with the sizes
of 2230, 2242, 2260, 2280
• Backward compatible with the USB 3.0/2.0 interface thanks to the
attached USB-C to USB 3.0 cable.
• Plug & Play function support
• Active LED diodes indicating the case state (illuminates - is connected,
flashes - a writing/reading procedure in progress)
• RAID field switch
• Power supply 5V, 900mA
• Weight: 165 g
• Dimensions: 125 x 78 x 20 mm
SYSTEM REQUIREMENTS
Windows 7/8/8.1/10 32/64bit, Mac OS 10.x and higher – automatic installation
of the drivers from the system.
Free USB-C or USB-A port.
RESET BUTTON
RAID CONTROLLER SWITCH
4 |
ENGLISH
All manuals and user guides at all-guides.com
SLOT 2
SLOT 1
M.2 DISK HARDWARE INSTALLATION
Proceed according to the following instructions:
1. Put out the inner part with the motherboard.
2. Insert M.2 disks so that the slot in the disk complied with the slot on the
M.2 connector. Afterwards screw the M.2 disks on the contrary side to the
motherboard.
3. Set the RAID field - see article "RAID field setting".
4. Put this set back in the case and screw it from the bottom part.
5. Glue legs on the bottom side of the case.
6. Connect the USB-C or USB-C/A cable to the case and to the computer.
7. Switch-over the ON/OFF switch to the ON position.
8. Detection and automatic installation will be performed.
9. Now the device is ready for use.
RAID FIELD SETTING
Attention: By changing the setting, you will always lose your already saved
data.
1. At the switch, select one of four options of connection of the disks in
dependence on the need of use.
A) Raid 0 – stripping/sum of disks, writing to the both simultaneously,
interlaced (flash the both LED). A benefit is a high writing/reading speed.
Attention: In case of a failure of one of the disks, all data will be lost
B) JBOD/separate disks – There is reported as two separate disks in
the system (flashes LED depending on a disk to which the record is being
performed)
C) JBOD/disks capacity sum – There is reported as one disk with a capacity
of the sum of the inserted disks (consecutive writing to one and afterwards to
the second disk, LED flashes depending on a disk to which the record is being
performed)
D) Raid 1 – Mirroring (both LEDs flash at writing, in case of reading –
just one). In case of a failure of one of the disks, data will not be lost.
2. While the case is connected and switched-on, push the Reset button for 5
seconds. The RAID field will be readjusted.
3. Format the disks.
Quick Start
ENGLISH
| 5