Options; Characteristics; Default Programming Setting - Favero FIGHT TIMER 150 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EXAMPLES OF PROGRAMMING
Following are several examples of how each
of the 5 Timers can be programmed to obtain
different modalities of functioning.
Single Action
Indicated for visualizing the time of a
competition with the final audio signal.
To program: xA= Time of Action, xP=0, xC=1
and xF=0.
Fixed number of cycles
Indicated for visualizing the time of
competitions repeated on various occasions.
To program: xA= Time of Action, xP= Time of
Pause, xC= Number of cycles, xF=0.
Infinite number of cycles
Indicated for continuous sequences of
training; it can be interrupted only by pressing
the
START-STOP
key.
To program: xA= Time of Action, xP= Time of
Pause, xC=0, xF=0.
Sequences with a fixed Number of cycles and
Final Pause.
Indicated for training sequences with recovery
times (pause) of differing duration. After the
Final Pause the entire cycle is repeated; it can
be interrupted only by pressing the
STOP
key.
To program: xA= Time of Action, xP= Time of
Pause, xC= Number of cycles, xF=Time of
Final Pause.
Combination of two Timers.
The activation of a Timer and the booking of
another timer allows to considerably increase
the combinations of the time count. For
example, among the many possibilities, the
count of a certain number of cycles of
Action+Pause may be performed, followed by
a different number of cycles with different
durations of Action+Pause (see Fig. 2).
Fig. 2: Examples of Timer combinations
1° Timer
Action Pause1
Action
Action
Pause2
5 min
1 min
5 min
1 min
START-
2° Timer
Pause1
Action
F.Pause
Action
5 min
3 min
1 min
10 min
10 min

OPTIONS:

Infrared REMOTE CONTROL (art. 150-02)
The remote control allows to control, without
cables, all of the functions for a distance of up
to 15m. It is not included with the FIGHT
TIMER and can be ordered separately, also at
a later date.
CASE (art. 852)
It is possibile to order the practical transport
case for the table version of FIGHT TIMER.

CHARACTERISTICS

Power supply:
- 2
30 Vac ±10%; 50 Hz; 6VA
- 115 Vac ±10%; 60 Hz; 6 VA
Conditions:
- functional:
-
of stocking:
Numbers:
-
dimension:
-
visibility:
Size:
-
wall version:
-
table version:
Remote control:
-
size:
-
range:
-
battery:
Case:
-
60 x 40 x 11.4 cm; 2.3 kg
DEFAULT PROGRAMMING SETTINGS
Parameter
H1
H2
H3
1A
1P
1C
1F
2A
F.Pause
2P
20 min
2C
2F
6
0 .. +50 °C; UR < 95%
-15 .. +70 °C; UR < 95%
9.1 x 4.3 cm
> 30 m
56 x 18.5 x 4.0 cm; 1.6 kg
56 x 23 x 18.5 cm;2.1kg
4.9 x 11 x 2.2 cm; 0.18 kg
> 15 m
9V; 16 x 45 x 26 mm; 2 years
Description
Modality of count
Type of sound
Sound volume
Timer 1 -
Time of action
Timer 1 -
Time of pause
Timer 1 -
Number of cycles
Timer 1 -
Time of Final Pause
Timer 2 -
Time of action
Timer 2 -
Time of pause
Timer 2 -
Number of cycles
Timer 2 -
Time of Final Pause
ENGLISH
Default value
up
2 = Contin.
2 = Middle
3':00"
1':00"
6
0':00"
2':00"
1':00"
3
0':00"

Publicidad

Tabla de contenido
loading

Productos relacionados para Favero FIGHT TIMER 150

Tabla de contenido