Commissioning - Schneider Airsystems KNG 40 SYS Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
GB
KLG / KNG / SNG
WARNING
Penetration of thin workpieces or edges
possible!
Avoid or pay close attention!
CAUTION
Vibrations transmitted from device to
operator during load operation.
Beware
Wear safety gloves
CAUTION
Dangerous obstacle!
Air hoses laid on the ground.
Avoid or pay close attention.
NOTICE
Do not use device for hard surfaces
such as concrete, metal or similar mate-
rials!
• Protect yourself and other persons, ani-
mals, property, and the environment by
taking the necessary protective measures
and being trained in use of the devices to
prevent harm to your health, property
damage,
financial
harm or risk of accident.
• Be calm and focused and ensure proper
operation.
• Repairs may be carried out only by
Schneider Druckluft GmbH or its approved
service partners.
• Prohibited: manipulation, inappropriate
use, temporary repairs, use of other ener-
gy sources, removal or use of damaged
safety equipment, operating a leaking or
malfunctioning system, use of non-original
spare parts, exceeding the permitted
working pressure specified (max. + 10%),
II/ 8
loss,
environmental
working without protective equipment,
transporting / maintaining / repairing or
leaving a pressurised machine unattended,
using other / unsuitable lubricants, smok-
ing, naked flames, removing stickers.
• Prohibited: Use of fastening materials
other than those specified, storage with full
magazine.
• Prohibited: Touching trigger safety device
(item 06) or guide plate (item 07).
2.4

Commissioning

Before start-up:
1. Observe technical data, figures, item
numbers, intended use and safety in-
structions
(see Instruction manual, Part 1, Chap-
ter: "Technical data" and the "Intended
use" chapter).
2. Carry out a visual inspection.
3. Do not use below 5° C.
4. If supplied separately: attach plug nip-
ples (item 01).
Load fasteners:
1. Lift the catch lever (item 03) and open
the magazine slide (item 05) (Fig. 2a).
2. Load the correct fasteners into the bot-
tom / side / top-loading magazine
(item 04) (Fig. 3a).
(see Instruction manual, Part 1, Chap-
ter: "Technical data" and the "Intended
use" chapter).
3. Close the magazine slide (item 05) and
allow the catch lever (item 03) to en-
gage.
Compressed air connection:
1. Install an upstream maintenance unit
with filter pressure reducer and mist oil-
er.
2. Press the quick-action coupling of the air
hose onto the plug nipple (item 01)
(Figure 1a).
Operation:
1. If
available:
(item 10)
2. Set the required pressure
3. If available: adjust the depth setting
(item 08) (Fig. 4a).
release
the
interlock

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

D300044

Tabla de contenido