English
To replace the screw down (6.I), remove the
cap (6.C) and the grub screw (6.B) and pull
out the handle (6.A). Loosen the grub screw
(6.E) and remove the knob (6.D). Once the
plate (6.F) has been removed, screw on the
stop cocks (6.L) in clockwise direction using a
screwdriver, then disassemble the screw (6.G)
and the joint (6.H). Using a wrench, remove
and replace the screw down (6.I). Carefully
clean the support sealing surfaces of the
gaskets and reassemble in reverse order. Do not
force the grub screw (6.E) so as to not cause
malfunctions or damages.
FIG. 07
To replace only the handle (7.I) follow the
instructions given below:
Pull out the cap (7.G), loosen the grub screw
(7.H) and remove the handle (7.I) with the knob
(7.D).
DO NOT move the bar of the new cartridge
(7.O) so as to not compromise the calibration.
Reassemble the new handle (7.I) and lock it with
the grub screw (7.H). Complete the installation
by inserting the cap (7.G).
To replace the thermostatic cartridge (7.O)
remove the cap (7.C), loosen the grub screw
(7.B) and pull out the handle (7.A). Remove the
grub screw (7.E) and pull out the knob (7.D).
After disassembling the plate (7.F) screw on the
stop cocks (7.Q) in clockwise direction using a
screwdriver.
To replace the thermostatic cartridge with the
handle (7.R) follow the instructions given below:
remove the grub screw (7.P) and pull out the
thermostatic cartridge with the handle (7.R).
Install the new assembly (7.R) into the faucet
housing carefully aligning the positioning hole
with the housing of the grub screw (7.P). Tighten
the grub screw without forcing it to prevent
malfunctioning or damages.
To replace only the thermostatic cartridge (7.O)
follow the instructions given below:
Remove the grub screw (7.P) and pull out of the
body the thermostatic cartridge with the handle
(7.R). Remove the cap (7.G) from the assembly,
loosen the grub screw (7.H) and pull out the
handle (7.I). Disassemble the ring (7.L), the lock
nut (7.M) and the peg (7.N) from thermostatic
cartridge (7.O).
Install the new cartridge (7.O) in the faucet
housing aligning the positioning hole with the
Based on its policy of steady development Fortis reserves the right to change the characteristics
of the products without notice and therefore the images and data contained in this catalogue may vary.
Istruz. art. 8569000.indd 7
grub screw housing (7.P). Tighten the grub screw
without forcing it to prevent malfunctioning or
damages.
DO NOT move the bar of the new cartridge
(7.O) so as to not compromise the calibration.
Install the temperature adjustment lock nut
(7.M) as shown, then carefully tighten the peg
(7.N). Assemble the assemble the handle (7.I)
positioning the ring (7.L) in between. Lock it with
the grub screw (7.H) and complete by inserting
the cap (7.G).
Once completed the replacement, remove the
stop cocks (7.Q) turning them in anti-clockwise
direction using a screwdriver. Reassemble the
plate (7.F), fit the handle (7.A) and lock it with
the grub screw (7.B) and insert the cap (7.C).
Fit the knob (7.D) on the handle (7.I) fastening it
with the grub screw (7.E).
FIG. 08
The figure shows the faucet correctly assembled.
Start the water flow by rotating handle (8.A)
by 90° clockwise, adjust the temperature using
handle (8.B).
MAINTENANCE OF THE SURFACES
Before cleaning, make sure the faucet is cold
(heat wears the surface of the faucet down). Do
not use products containing acids or corrosive
substances. Wipe the faucet daily with a soft
cloth. Do not use steel wool or metal pads,
abrasive sponges or similar products. Right
after cleaning rinse off the detergent residues
with cold water. Damages to the faucets caused
by incorrect treatment are not covered by the
warranty.