Fan Settings; Using The Fan - Xpelair Simply Silent C6S Instrucciones De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
F
FAN
TERMINALS
• For fixed wiring circuits the protective fuse for the appliance must not exceed 5A.
• Terminal E can be used as a parking terminal for an earth wire (if required)
FAN
TERMINALS

Fan Settings

SPEED SETTING
The fans are factory set to low speed, but have
two speed settings for different applications.
Select either high or low speed by connecting
the jumper between the centre and high or low
speed pin on the jumper (see Figure E)
C6TS / C6TR Only.
• To adjust the over-run period turn the control
(T) clockwise to increase and anti-clockwise
to decrease – see Figure D.
C6HTS /C6HTR Only – see figures D and E.
• The pre-set humidity operation is factory set
at approximately 75% Relative Humidity (RH),
but can be adjusted between 65% and 85%
RH by control H.
• The over-run timer is factory set at 15 minutes
but can be adjusted from 30 seconds to 30
minutes by control T.
• Turn the controls clockwise to increase RH or
time and anti-clockwise to decrease.

Using the fan

C6S / C6R Only
• Operate the fan using the on/off switch (not
supplied). Repeat to switch off.
ON/OFF
SWITCH
LAMP
(IF REQUIRED)
C6S/C6R
C6PS/C6PR
DOUBLE POLE
ISOLATING SWITCH
FUSE
C6TS/C6TR
C6HTS/C6HTR
DOUBLE POLE
ISOLATING SWITCH
FUSE
C6PS / C6PR Only
• Operate the fan by pulling and releasing the
cord. Repeat to switch off.
C6TS /C6TR Only
• Operate the fan using an on/off switch (not
supplied). When the switch is turned off,
the fan continues to operate for the set time
delay. To adjust the over-run period, turn the
control "T" clockwise to increase and anti-
clockwise to decrease – see Figure F.
C6HTS /C6HTR Only.
• Automatic mode - The fan automatically
adjusts to slow changes in natural humidity
levels without operating the fan. If the humidity
levels increase at a rate slower than 5% RH
in 5 minutes, up to the pre-set humidity level,
the fan will not be triggered by humidity. This
is to prevent nuisance triggering of the fan. If
humidity levels increase quicker than 5% RH
in 5 minutes the fan will operate. When relative
humidity drops the fan continues to operate for
the adjustable time delay.
• External operation - Use the external on/off
switch. When the fan is switched off, the fan
continues to operate for the adjustable time
delay then goes into automatic mode.
All Fans
Re-fit the front cover/baffle assembly by hooking
in the top first, and then swing the cover down
to clip into place.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Simply silent c6rSimply silent c6tsSimply silent c6trSimply silent c6psSimply silent c6prSimply silent c6hts ... Mostrar todo

Tabla de contenido