ATP 1555 Guia De Inicio Rapido página 3

Tabla de contenido

Publicidad

ATP
1555.A92 INSIDE TRIGGER HANDLE ASSEMBLY BILL OF MATERIALS
ATP
A DIVISION OF HY-TECH ENGINEERED SOLUTIONS
25 LEONBERG ROAD * CRANBERRY TOWNSHIP, PA 16066
CALL (724) 776-6800 OR TOLL FREE 1-800-245-1148
ATP
ATP 1555
Tool Model
Number
1555EI-TH
1555EO-TH
1555EI-5S
1555EO-5S
Year of manufacture:
Operating conditions, reference ISO 15744:
A-weighted sound power level, L
Uncertainty, K
A-weighted emission sound pressure level at the
work station, L
Uncertainty, K
C-weighted peak emission sound pressure level,
L
pC,peak
Uncertainty, K
NOTE 1:
NOTE 2:
*These declared values were obtained by laboratory type testing in compliance with the stated standards and are not adequate for use in risk assessments. Values measured in individual work
places may be higher than the declared values. The actual exposure values and risk of harm experienced by an individual user are unique and depend upon the way the user works, the work
piece and the workstation design, as well as upon the exposure time and the physical condition of the user. We, Hy-Tech Engineered Solutions, cannot be held liable for the consequences of
using the declared values, instead of values reflecting the actual exposure, in an individual risk assessment in a work place situation over which we have no control.
ATP
A DIVISION OF HY-TECH ENGINEERED SOLUTIONS
25 LEONBERG ROAD * CRANBERRY TOWNSHIP, PA 16066
www.hy-techinc.com
CALL (724) 776-6800 OR TOLL FREE 1-800-245-1148
Declaration of Vibration Emission per EN 12096
Values determined according to EN ISO 28927-2
Tool Type
Operating
Conditions
1-1/2" End Grip
Pressure at which
Inside Trigger
tool is operated
1-1/2" End Grip
As above
Outside Trigger
End Grip Inside
As above
Trigger #5 Spline
End Grip Outside
As above
Trigger #5 Spline
Declared dual number noise emission values
in accordance with ISO 4871
Power tool tested
Manufacturer:
Hy-tech Engineered Solutions
Model No.
ATP1555
Type:
Impact Wrench
Serial No.
ATP1555EI-TH-1
2019
:
WA
:
WA
:
pA
:
pA
:
:
pC,peak
Values determined according to noise test code ISO 15744, using, as basic standards, ISO 3744
and ISO 11203.
The sum of a measured noise emission value and its associated uncertainty represents an upper
boundary of the range of values which is likely to occur in measurements.
ATP 1555
Measured Vibration
Uncertainty
Emission Value
k
a
107.1 m/s
2
1.5 m/s
2
107.1 m/s
2
1.5 m/s
2
2
2
107.1 m/s
1.5 m/s
2
2
107.1 m/s
1.5 m/s
Inserted tool:
ATP1555EI-TH
No-load speed:
637.9 r/min
Capacity:
Not Applicable
Blow frequency:
10.63 Hz
No Load
On Load
118.03dB
117.07dB (reference 1 pW)
3dB
3dB
107.03dB
106.07dB
(reference 20 μPa)
3dB
3dB
115.84dB (reference 20 μPa)
122.9dB
3dB
3dB
www.hy-techinc.com