230V ~
N L
P1
10A
230V ~
Optional pushbuttons
3. REPEAT FUNCTION ACTIVATION
•
Enter device programming mode, hold the button
while the device is in stand-by. Access to the programming mode is confi rmed by a sound of three
beeps and by the visual signal of the MUTE icon
•
Hold the button pressed for 3 seconds until the green LED
•
Exit programming mode by holding the button pressed for a long time. Two beeps will confi rm closing
the programming mode and the MUTE
When the call repeat service is active, the green LED
Once the function has been activated, the button
programming mode will not activate any function previously associated with the button.
The function will be active even if the MUTE function is enabled on the video door phone.
To deactivate the function, repeat the same procedure used for activating it.
TECHNICAL SPECIFICATIONS
Power voltage: ............................................................................................................................... 36 ÷ 48 V
Consumption: .................................................................................................................................... @ 48 V
Standby: .................................................................................................................................... < 3,5 mAcc
Full rate: ................................................................................................................................... < 245 mAcc
Wires with cross-section area of 0.5 mm
cross section area smaller than 0.5 mm
KEY TO SYMBOLS
Symbol
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, URMET S.p.A. declares that the radio equipment type:
2 VOICE VIDEO 7" SOFT TOUCH Ref. 1719/1 or 1719/2
is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.urmet.com
DS1719-004
Before programming, briefl y press button P1 or P2 23 times to
unlock the relay. The module will blink 3 times.
Briefl y press button P1 or P2 22 times to program the blinking
P2
mode. The module will blink twice.
icon will stop blinking.
2
must comply with IEC 60332-2-2.
2
Direct input voltage
See the installation manual of the device
pressed for a long time (longer than 5 seconds)
that starts blinking.
will light up in programming mode.
will be disabled. Pressing the button
or larger must comply with IEC 60332-1-2; wires with
Description
lights up.
not in
21