4.1.4
INSTRUCTIONS
SILENCER HOUSINGS
Danger
due
Impeller!
There may be a danger of shearing due to the impeller
rotating even when the machine is switched off, if it is
started manually.
Suitable working clothes and personal protective equipment
must therefore be used.
The SCL K-MS series is designed to provide maximum flexibility
in positioning the silencer housings, to allow for various
installation configurations.
The blower comes with the silencers positioned as shown in fig
1.
If this layout has to be modified, proceed to identify the layout of
the silencer housings required.
The possible solutions are shown in fig 2, fig 3, and fig 4 below.
fig 2
fig 2 with 90° manifold
_________________________________________________
fig 3
fig 3 with 90° manifolds
90° manifolds
FOR
REPOSITIONING
to
rotating
components:
fig.1
90° manifold
THE
fig 4
fig 4 with 90° manifold
_________________________________________________
Position the unit in a horizontal position with the bracket on a
flat, stable surface.
Disassembling the silencer housing:
- Remove the bolts (906).
- Remove the silencer (700) with its gasket (424).
Fitting the blank flange (730):
- Remove the bolts (909) and the flange (730) with the O-Ring
(427).
162
909
730
427
Fit everything again in reverse order, not forgetting gaskets
(424), and (427).
USING THE (accessory) CK TYPE 90° MANIFOLD KIT
The 90° manifold can only be fitted for (162) cover openings
and as shown in fig 2, fig 3, and fig 4 above there are a number
of installation configurations that are possible.
The CK type 90° manifold kit comprises:
N° 1 manifold
N° 1 gasket (427) and
N° 2 M8x25 UNI 5739 bolts
To assemble the 90° manifold proceed as follows:
- Remove the silencer housing as described before.
- Put the gasket between the cover (162) and the 90° manifold,
and tighten the M8x25 UNI 5739 bolts.
- Assemble the silencer housing, following the instructions in
reverse order and not forgetting gasket (424).
GB - 21/63
90° manifold
424 906 700