APPROPRIATE USE

Aquastop SHT 216 is a device for detecting water level changes. When the sensor gets in
contact with water, an audible and/or visual alarm signal is raised and the device connected
is deactivated.
The device may only be used as previously described.

INSTALLATION INSTRUCTION

Warning: Do not use the device outside!
Sensor installation
The sensor reacts to water contact at
the two metal contacts.
The assembly height of the sensor
defines, at what level the water detec-
tor will sound an alarm.
For quick warning in case of water
ingress, you mount the sensor close
to the floor, so both sensor contacts
touch the ground.
For installing the sensor use the
provided assembly material.
STARTUP
The SHT 216 water detector just has to be plugged into the socket (230 V AC / 50-60 Hz).
Connect the power plug of the washing machine or dish washer to the earthed socket of the
SHT 216. The locking of the power plug helps to avoid unintended removal of the device plug.
The LED (Function) lights up green and signals that the device is ready for use.
ALARM
As soon as the sensor has contact with water, an acoustic and an optic alarm signal sounds.
The LED lights up red. The device connected is deactivated. The alarm remains active until
Aquastop SHT 216 is disconnected from the power line and the water doesn't contact the
sensor any more.

FUNCTION TEST

Function test of the device: touch both sensor contacts with a waterlogged cloth or an electric
conductive metal and the alarm is set off immediately. The device connected is deactivated.
The alarm is deactivated as soon as you briefly disconnect Aquastop SHT 216 from the
power line and remove the cloth from the metal contacts.
For your safety, we recommend that you carry out this test constantly!