OPERATION MANUAL AND INSTRUCTIONS
Troubleshooting
Always disconnect air supply before checking the pneumatic tool for failures or cleaning it, and empty the magazine; this precaution
will prevent the pneumatic tool from being accidentally started.
FAILURES
Fixing part jammed
No fixing part is ejected
Fixing part cannot be fitted in
completely
Other failures
Periodically, depending on the frequency of use, clean the pneumatic tool. If any operation defects that cannot be dealt with
through the instructions should be shown, send the pneumatic tool to the repair centre.
POSSIBLE CAUSES
Fixing part loaded incorrectly.
Unsuitably sized fixing part.
Bits of glue or wood powder in
magazine or guide.
Low pressure in air supply
system.
Low pressure in air supply
system.
SOLUTIONS
Check that fixing machine has been correctly loaded
as follows:
1) Open the magazine (picture 3).
2) Release the safety trigger on the door side (picture
4).
3) Open the front door, and remove the jammed
staple or nail (picture 4).
4) Close the door. Make sure that the lever locks the
door safely.
5) Load the staples or nails, and check that they slide
easily.
6) Push the magazine as much as required to close
it fully
Connect air supply to fixing machine and operate it.
Check dimensions of fixing part by comparing them
with dimensions stated in TECHNICAL DATA table.
Remove bits of glue or wood powder.
− Check compressed air supply system.
− Check output pressure.
− Check compressed air supply system.
− Check output pressure.
− Contact repair centre.
EN
13