Bathroom Exhaust
Fan/Light Combination
MODEL: 8663RP, 8673RP, 8664RP
Suitable for use in shower or tub enclosure when used
with GFI protected branch circuit.
Suitable for use in insulated ceilings.
WARNING: To reduce the risk of fire or electrical shock, do not use this
fan with any solid-state speed control device. Do not install in a ceiling
insulated to a value greater than R-40.
IMPORTANT SAFETY INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at Service Panel and
lock Service Panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-rated
construction.
B. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire Protection
Association (NFPA),
and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application.
F. NEVER place a switch where it can be reached from a tub or shower.
FOR BEST RESULTS
When installing the Exhaust Fan/Light in a new construction site, install
housing during the rough-in construction of the building. The blower unit,
reflector and grille should be installed after the finished ceiling is in place.
Refer to instructions on page 3 to install the Exhaust Fan/Light in an
existing finished building.
PLANNING DUCTWORK AND WIRING
1. Use 4" round duct.
2. Plan duct run from discharge opening of fan to the outside. For best fan
performance, make duct run as short as possible and use minimum
number of elbows.
3. Use optional NuTone ducting accessories as needed.
READ & SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
Slots
Night Light
Socket
(not provided
on 8664RP)
IMPORTANT: Use wire suitable for 90°C.
Plan to run 120vAC house wiring (with ground) from power source, through
wall switches, to junction box in fan. For separate control of fan, light, and
night light three wall switches are required. See NuTone Catalog for accessory
switches. For separate control of fan, light, and night light, five conductors are
needed between the wall switch box and the fan's junction box. (Night light
not provided on 8664RP).
INSTALLATION IN A NEW
CONSTRUCTION SITE
PREPARATION
1. Refer to Figure 1. Remove power unit/blower assembly from housing.
A. Unplug power unit.
B. Remove screw (located next to plug-in receptacle) which holds
power/blower unit mounting plate in place. Save screw.
C. Lift mounting plate at end near the plug-in receptacle until blower
wheel clears the scroll.
D. Remove plate by pulling its tabs out of slots in housing. Set
power/blower unit aside until needed.
2. Remove one of the wiring knockouts from housing.
Wiring
Knockouts
Housing
Scroll
Power/Blower
Unit
Reflector
Assembly
Wing Nut
Mounting
Springs (2)
Grille/Lens
Assembly
FIGURE 1

Publicidad

loading

Resumen de contenidos para NuTone 8663RP

  • Página 1 For separate control of fan, light, and Engineers (ASHRAE), and the local code authorities. night light three wall switches are required. See NuTone Catalog for accessory C. When cutting or drilling into wall or ceiling, do not damage electrical wiring switches.
  • Página 2 2. Insert and secure an approved box connector into wiring entrance hole. 3. Pull wires through box connector and into junction box. Tighten box connector. 4. Refer to Figure 4A. (For 8663RP or 8673RP) Connect white wires from the fan and light receptacles to white (neutral) wire from the supply.
  • Página 3 POWER/BLOWER UNIT INSTALLATION 11-1/2" 1. Refer to Figure 1. Place power/blower unit into housing so that mounting plate's tabs insert into slots in housing. 2. Press other end of mounting plate down until it is firmly seated over scroll and 5-3/4"...
  • Página 4 Pour une C. Lorsque vous coupez ou percez dans un mur ou un plafond, n’abîmez pas le commande séparée du ventilateur et de l'éclairage, utiliser un interrupteur NuTone câblage électrique ou tout autre installation encastrée.
  • Página 5 3. Tirer les câbles par le raccord jusque dans le boîtier de raccorde-ment. Serrer le raccord. 4. Voir Figure 4A pour les modéles 8663RP ou 8673RP. Relier les câbles blancs des prises du ventilateur et d'éclairage au câble blanc d'alimentation générale (neutre.) Relier le câble noir au câble provenant de l'interrupteur du ventilateur.
  • Página 6 INSTALLATION DU BLOC-MOTEUR 11-1/2" 1. Voir Figure 1. Placer le bloc-moteur dans le boîtier de sorte que les pattes de la plaque de montage s'insèrent dans les fentes du boîtier. 2. Appuyer sur l'autre extrémité de la plaque de montage pour la faire descendre 5-3/4"...
  • Página 7 Para obtener el control separado del ventilador, la luz y la luz de noche se otros servicios escondidos. necesitan tres interruptores de pared. Consutle el Catálogo NuTone para ver los D. Los ventiladores entubados siempre deben estar ventilados hacia el exterior.
  • Página 8 NOCHE Aprete el conectador de caja. 4. Consulte la Figura 4A para modelo 8663RP o 8673RP. Conecte los cables blancos de los receptáculos del ventilador y de la luz la cable blanco (neutro) de la alimentación. Conecte el cable negro al cable del interruptor del ventilador. Conecte el cable rojo al cable del interruptor de la luz.
  • Página 9 INSTALACION DE LA UNIDAD 11-1/2" DE POTENCIA/SOPLADOR 1. Refiérase a la Figura 1. Coloque la unidad de potencia/soplador en la caja para que las lengüetas de la placa de montaje se inserten en las ranuras de la caja. 5-3/4" 2. Presione el otro extremo de la placa de montaje hasta que esté firmemente asentada sobre los receptáculos de espiral y de clavija.
  • Página 10: Garantía Limitada De Un Año

    One Year Limited Warranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Página 11: Parts List

    32788-000 51919 BLOWER WHEEL 8663RP, 8673RP, 8664RP 5900A-000 Parts list continued... NuTone NOTE: Always order by Attn: Parts Department current part number 4820 Red Bank Rd. Cincinnati, OH 45227-1599 8663RP, 8673RP & 8664RP I.I. Phone: (513) 527-5426 Fax: (513) 527-5173...
  • Página 12 8663RP, 8673RP, 8664RP 10034-000 36892 LIGHT RECEPTACLE 8663RP, 8673RP, 8664RP 36892-000 82304 LIGHT RECEPTACLE 8664RP 82304-000 85938 SQUARE BEZEL 8673RP 85938-000 89248 REFLECTOR ONLY 8663RP, 8673RP, 8664RP 89248-206 NOTE: Always order by current part number 8663RP, 8673RP & 8664RP I.I.