Voltage compensation
Because of some voltage drop in the cables, the actual voltage at the clamps of the battery can be lower than
the charger output voltage. A special circuitry inside the unit will monitor the true input voltage to the battery
and adjust the output voltage of the
unit accordingly. This will maximize the charging efficiency.
Reverse-polarity protection
This unit offers reverse-polarity protection, the RED "REVERSE" LED will illuminate and the charging process
will not start. If this happens, unplug immediately from mains,
connect the red crocodile clip to positive (+) battery post, and black crocodile clip to
negative (-) post, then plug into the mains power and the charging process will start.
Short-circuit protection
Should you accidentally touch the HD75A clips together whilst the mains power is on, the unit will not perform
charging. Unplug from mains, disconnect and start the process again being careful not to touch the clips
together.
Charger memory
In the event of a black-out or loss of AC power, the charger will automatically memorize the charging state.
When AC power is restored, the charging will continue in the previous charging state.
ATTENTION:Once the clamp of charger is disconnected from the battery, this memory is erased and the
charging will restart from the first charging state.
Other features
Anti Spark Protection
•
Battery and Charger Overheating Protection
•
Waterproof ABS Housing.
•
Ingress Protection Rating IP65
•
3- OPERATION
PLEASE READ CAREFULLY BEFORE USING
Suitable for 12V Normal Lead Acid, Sealed, Leisure or Gel Batteries between 7-75Ah.
1. Charging your battery
It is essential to disconnect the battery from the car. This will avoid possible damage to the alternator. To
avoid damage to the bodywork from possible spillage, remove the battery completely from the vehicle. It is
advisable to use gloves when handling the battery, as there is a high possibility of corrosive acid being on
the outside of the battery.
2. Preparing the battery
Firstly remove the caps from each cell and check that the level of the liquid is sufficient in each cell.
If it is below the recommended level, top up with de-ionized or distilled water.
Note: Under no circumstances should tap water be used.
The cell caps should not be replaced until charging is complete. This allows any gases formed during
charging to escape. It is inevitable that some minor escape of acid will occur during charging.
For permanently sealed battery, it is not necessary to carry out the above checks.
3. Connection
The INVERCAR 530 has two options for connecting the unit to the battery.
Via the intelligent cable connector you can select witch connection you want to use:
HD75A clamps for easy and flexible use.
•
O-ring connectors for permanent fixation on your battery.
•
please cover the connector when it is not in use.
It is important to ensure that both DC clamps are making good contact with their respective terminal posts.
Connect the charger's AC power cable to an AC power outlet. Once you have connected the INVERCAR 530
battery charger to AC power, the Simple Touch power panel LEDs light for two seconds.
A protection plastic end cap is provided,
(
)
MI03064-01