Specifications
H4635
Type of Hydraulic System: Open-center
or closed-center
Hydraulic Ports:
Pressure (supply): 1/2" male NPT
Tank (return): 1/2" male NPT
Output: Refer to the "Performance Chart" below
Mass/Weight: 10.9 kg (24 lb)
Width (diameter): 301 mm (11.87")
Height (with handle): 360 mm (14.18")
Maximum Trash Diameter: 63.5 mm (2.5")
Pump Inlet Port: 79.4 mm (3.125")
Pump Discharge Port: 3" female NPT
Performance Chart
33.5 m (110 ft)
37.9 l/min
(10 gpm)
30.5 m (100 ft)
27.4 m (90 ft)
34.1 l/min
(9 gpm)
24.4 m (80 ft)
30.3 l/min
21.3 m (70 ft)
(8 gpm)
18.3 m (60 ft)
26.5 l/min
(7 gpm)
15.2 m (50 ft)
12.2 m (40 ft)
9.14 m (30 ft)
6.10 m (20 ft)
3.05 m (10 ft)
0
0
189
379
568
(50)
(100)
(150)
Pump Discharge Flow — l/min (gpm)
Hydraulic Power Source
Do not exceed the following hydraulic power source
maximums:
•
Hydraulic flow: 37.9 l/min (10 gpm)
•
Pressure relief: 172 bar (2500 psi)
•
Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe
injury or death.
Greenlee / A Textron Company
757
946
1136
1325
1514
1703
(200)
(250)
(300)
(350)
(400)
(450)
H4635 Submersible Trash Pump
Hydraulic Power Source (cont'd)
Type of Hydraulic System: Open-center
or closed-center
Flow:
Minimum: 26.5 l/min (7 gpm)
Recommended: 30.3 to 37.9 l/min (8 to 10 gpm)
Maximum: 37.9 l/min (10 gpm)
Filtration: 10 micron (nominal)
Pressure Relief Setting: 172 bar (2500 psi)
Back Pressure (maximum*): 13.8 bar (200 psi)
* 13.8 bar (200 psi) is the maximum agreed standard back pressure
for the HTMA (Hydraulic Tool Manufacturers Association).
Greenlee Utility tools will operate satisfactorily at this standard.
1. Maximum hydraulic fluid temperature must not
exceed 60 °C (140 °F). A sufficient oil cooling
capacity is needed to limit the hydraulic fluid
temperature.
2. Hydraulic flow must not exceed 37.9 l/min (10 gpm).
Install a flow meter in the return line to measure the
rate of hydraulic flow before using the tool.
3. Pressure relief valve setting must not exceed
172 bar (2500 psi) at your tool's maximum flow.
Locate the pressure relief valve in the supply circuit
to limit excessive hydraulic pressure to the tool.
Hydraulic Schematic
RESERVOIR
1893
(500)
PUMP
POWER SOURCE
Recommended Hydraulic Fluids
Use any nondetergent, petroleum-based hydraulic
fluid which meets the following specifications or HTMA
specifications.
S.U.S. @:
38 °C (100 °F): 140 to 225
99 °C (210 °F): 40 minimum
Flash Point: 170 °C (340 °F) minimum
Pour Point: –34 °C (–30 °F) minimum
6
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
FILTER
(10 MICRON)
RELIEF
COOLER
VALVE
172 bar
(2500 psi)
T
CONTROL
VALVE
FLOW METER
P
TOOL