2021-03-25
The machine must be switched off and locked and tagged prior to any ser-
vice repair work (electric and pneumatic power switched off).
The heat platen can cause burns. Check that the platen temperature reading
on the display panel is below 25° C before handling.
Problem
The machine does not
switch on
The platen does not heat
up
The platen overheats
The timer is not counting
down
The platen does not lower Leaking cylinder
The platen does not lift up Faulty solenoid control valve
The platen stays down af-
ter pressing
16

TROUBLESHOOTING TIPS

Possible causes
The plug is not connected
The switch has not been pressed
The emergency stop is activated
Faulty display panel
Faulty heating element
Problem with the automated system
Temperature setting too low
Problem with the probe or the tempe-
rature control
Disabled or faulty cylinder-mounted
sensor
Problem with the automated system
The solenoid control valve or the pro-
portional controller are faulty
Compressed air pressure too low
Leaking cylinder
Lack of compressed air
Solution
Check the mains electricity and that
the machine is plugged in.
Press the main On/Off switch to 1.
Turn the red button to release the
emergency stop
Check whether the cables are da-
maged (potential short circuit)
Check the connections and the
condition of the wires.
Contact your retailer to have the
heat platen removed.
Check the on-screen messages and
contact your stockist
See section 5 to change this setting
Check the on-screen messages and
contact your stockist
Check
its
position.
connections. Replace if necessary.
Check the on-screen messages and
refer to the manual or contact your
stockist.
Check the seals and all the connec-
tions. Cut the ends of the pipes.
Contact your retailer.
Check the valve couplings. Contact
your retailer about a possible repla-
cement.
Check that the supply pressure is
working.
Check the valve couplings. Contact
your retailer about a possible repla-
cement.
Check the seals and all the connec-
tions. Contact your retailer.
Check the compressed air system
Check
the
www.sefa.fr

Publicidad