Troubleshooting; Indicator Lights; No Audio - Clarion XH5210 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. TROUBLESHOOTING

Indicator lights

The XH510, XH5410 and XH7110 have lights that indicate amplifier status.
Blue top
Red end-
LED
panel light
On
Off
On
Alternating between
red and blue
Slow blink
Slow out-of-sync
blink
Quick blink
Quick in-sync
blink
 blinks,
 blinks,
then pause
then pause

No Audio

• Low or no remote turn-on voltage: check remote connections at the amplifier
and source unit.
• Blown amplifier fuse: replace with a new fast-blow fuse (same rating).
• Power wires not connected: check battery and ground wiring at the amplifier
and check the battery connections.
• Speaker leads shorted: check speaker continuity to ground; it should not show a
common ground.
• Speakers not connected or are blown: check speaker connections at the
amplifier and measure at speakers. Measure coil impedance at amplifier with
speaker wires disconnected.
Blue end-
panel light
Meaning
Off
Amplifier running normally
In thermal protection mode
Off
Over voltage;
reduce the input voltage
Off
Short circuit protection
Off
Repeated shorts detected;
remove the short circuit, wait
5 minutes for error condition
to clear; or clear condition by
removing the main power, for
example, by pulling the fuse.
XH510/XH5410/XH7110
1

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Xh5410Xh7110

Tabla de contenido