Flash Patterns:
POWER-UP RESET:
After installing the system it is best to do a POWER-UP RESET the first time
to ensure that all heads are in sync.
Touch BLUE wires to +V (RED wire) while applying power.
Release BLUE wires. All heads will reset to Pattern #2.
If you have installed a pattern select push-button, press and hold pattern
select while turning power switch ON.
To select a flash pattern, touch BLUE to +V or press pattern select switch to
increment the flash pattern. The heads will remember the selected pattern
even if power is removed.
#
Pattern:
1
Quad Flash
2
Double Flash
3
Triple Flash
4
DeciBlast
5
Single Flash
6
Mega Flash
7
Triple+Burst
8
Fast Mega
9
Cycle All
10
Double-Triple+Burst
11
Cycle Classic
12
Quad-Mega
13
Single-Quad
14
DeciBlast-Quad
15
Single-Triple-DeciBlast
16
Mega-Triple+Burst
STANDARD PATTERNS:
The HIDE-A-LED™ ships with only the standard patterns enabled (1 through
8). To enable cycle flash patterns follow the procedure below.
CYCLE PATTERNS:
You may add patterns 9 through 16 by following this procedure:
1) Touch BLUE wires to +V (RED wire) while applying power.
If you have installed a pattern select push-button, press and hold pattern
select while turning power switch ON.
2) Hold BLUE wires on +V for 5 SECONDS (heads will not be flashing during
this time). After 5 SECONDS the heads will flash once or twice to indicate the
flash pattern list that has been selected:
ONE FLASH = Standard Patterns only.
TWO FLASHES = Standard + Cycle patterns.
3) Remove the BLUE wires from +V (or release push-button).
You may switch the pattern set at any time as many times as you wish. All
heads will remember the pattern set that was selected even when power is
removed.
920-9063-00 Rev. E
STANDARD PATTERNS
Frequency:
Description:
1.25 Hz
75 Quad Flashes Per Minute
1.25 Hz
75 Double Flashes Per Minute
1.53 Hz
92.3 Triple Flashes Per Minute
1.42 Hz
85.5 Deci Flashes Per Minute
1.25 Hz
75 Single Flashes Per Minute
1.90 Hz
114 Single Flashes Per Minute
1.37 Hz
82.5 Triple+Burst Flashes Per Minute
3.0 Hz
180 Single Flashes Per Minute
CYCLE PATTERNS
Cycle through patterns 1 to 7
2 Double, 2 Triple+Burst cycle
1 Double, 1 Quad, 2 Mega cycle
3 Quad, 4 Mega cycle
2 Single, 2 Quad cycle
2 DeciBlast, 2 Quad cycle
2 Single, 2 Triple, 2 DeciBlast cycle
1 Mega, 1 Triple+Burst cycle
TroubleShooting:
HEAD NOT FLASHING:
Check the RED and BLACK wires for a reversed connection. (Reverse
connection will not damage the unit).
Check RED and BLACK wires for either a bad splice or a corroded
ground connection.
HEADS NOT SYNCHRONIZING:
Check for a short circuit on the BLUE wire to either +V or GROUND. Salt
water on the wire connections will short circuit the sync signal on the BLUE
wire. Check for non-functional heads in the system. If any one of the heads
has a bad GROUND connection it can cause the sync signal to become
corrupted. If any one of the heads has it's RED and BLACK wires reverse
connected it will corrupt the sync signal.
FLASH PATTERN CHANGING:
If the flash pattern changes on it's own there may be an intermittent short
between the BLUE wire and +V. Check for water in the wiring connections.
If any one of the heads in the system has an intermittent GROUND connec-
tion it can also cause the flash pattern to change.